Four Postmortem Case Reports with Quantitative Detection of the Synthetic Cannabinoid, 5F-PB-22
Open accessThe DOI matches its Crossref record.
Abstract
In January 2014, the US government temporarily designated 5F-PB-22, along with three other synthetic cannabinoids (AB-FUBINACA, ADB-PINACA and PB-22), into Schedule I. Over the course of a 4-month time period (July-October 2013), our laboratory quantitatively identified 5F-PB-22 in specimens obtained from four postmortem cases. We describe the four cases, to include pertinent autopsy findings and decedent histories, together with quantitative results for 5F-PB-22 determined in postmortem blood and antemortem serum. Samples were prepared via a liquid-liquid extraction at pH 10.2 into hexane : ethyl acetate. Instrumental analysis was achieved with liquid chromatography coupled with electrospray ionization tandem mass spectrometry operating in multiple reaction monitoring mode. Two ion transitions were monitored for the analyte of interest, and one ion transition was monitored for the internal standard. The observed concentration range of 5F-PB-22 is 1.1-1.5 ng/mL for three postmortem blood specimens and one antemortem serum specimen. Three of the decedents experienced abrupt, sudden death; however, one decedent expired after a rapidly deteriorating hospital course.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tait, R. J., Caldicott, D., Mountain, D., Hill, S. L., & Lenton, S. (2016) · Clinical Toxicology · doi:10.3109/15563650.2015.1110590 · Cited by 378
Novel psychoactive substances of interest for psychiatry
Schifano, F., Orsolini, L., Duccio Papanti, G., & Corkery, J. M. (2015) · World Psychiatry · doi:10.1002/wps.20174 · Cited by 321
Designer drugs: mechanism of action and adverse effects
Luethi, D., & Liechti, M. E. (2020) · Archives of Toxicology · doi:10.1007/s00204-020-02693-7 · Cited by 262
Toxicity of Synthetic Cannabinoids in K2/Spice: A Systematic Review
de Oliveira, M. C., Vides, M. C., Lassi, D. L. S., Torales, J., Ventriglio, A., Bombana, H. S., Leyton, V., Périco, C. D. A.-M., Negrão, A. B., Malbergier, A., et al. (2023) · Brain Sciences · doi:10.3390/brainsci13070990 · Cited by 61
“Author, Year, Country Synthetic Cannabinoid N (Sample); Age (Mean); Gender (M:F); Setting (O: Outpatient; I: Inpatient; ED: Emergency Department) Adverse Effects Lapoint et al., 2011, USA [34] JWH-018 1; 48; 1:0; ED Seizures, supraventriculartachycardia Schneir et al., 2011, USA [35] JWH-018, JWH-073 2; 21; 0:2; ED An…”
Influential
Metadata
- Authors
- Behonick, G., Shanks, K. G., Firchau, D. J., Mathur, G., Lynch, C. F., Nashelsky, M., Jaskierny, D. J., & Meroueh, C.
- Venue
- Journal of Analytical Toxicology
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-10
- Volume
- 38
- Issue
- 8
- Pages
- 559-562
- ISSN
- 0146-4760 (ISSN-L)
- 1945-2403
- OpenAlex
- W2043685462
- Cited by
- 165
- References
- 0
- FWCI
- 39.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Four Postmortem Case Reports with Quantitative Detection of the Synthetic Cannabinoid, 5F-PB-22. https://app.cochat.ai/papers/10.1093/jat/bku048
- The paper
- Behonick, G., Shanks, K. G., Firchau, D. J., Mathur, G., Lynch, C. F., Nashelsky, M., Jaskierny, D. J., & Meroueh, C. (2014). Four Postmortem Case Reports with Quantitative Detection of the Synthetic Cannabinoid, 5F-PB-22. Journal of Analytical Toxicology. https://doi.org/10.1093/jat/bku048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.