The origins and evolution of freeze-etch electron microscopy
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The introduction of the Balzers freeze-fracture machine by Moor in 1961 had a much greater impact on the advancement of electron microscopy than he could have imagined. Devised originally to circumvent the dangers of classical thin-section techniques, as well as to provide unique en face views of cell membranes, freeze-fracturing proved to be crucial for developing modern concepts of how biological membranes are organized and proved that membranes are bilayers of lipids within which proteins float and self-assemble. Later, when freeze-fracturing was combined with methods for freezing cells that avoided the fixation and cryoprotection steps that Moor still had to use to prepare the samples for his original invention, it became a means for capturing membrane dynamics on the millisecond time-scale, thus allowing a deeper understanding of the functions of biological membranes in living cells as well as their static ultrastructure. Finally, the realization that unfixed, non-cryoprotected samples could be deeply vacuum-etched or even freeze-dried after freeze-fracturing opened up a whole new way to image all the other molecular components of cells besides their membranes and also provided a powerful means to image the interactions of all the cytoplasmic components with the various membranes of the cell. The purpose of this review is to outline the history of these technical developments, to describe how they are being used in electron microscopy today and to suggest how they can be improved in order to further their utility for biological electron microscopy in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinesin superfamily motor proteins and intracellular transport
Hirokawa, N., Noda, Y., Tanaka, Y., & Niwa, S. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2774 · Cited by 1,859
Hirokawa, N., Niwa, S., & Tanaka, Y. (2010) · Neuron · doi:10.1016/j.neuron.2010.09.039 · Cited by 1,138
A High Precision Survey of the Molecular Dynamics of Mammalian Clathrin-Mediated Endocytosis
Taylor, M. J., Perrais, D., & Merrifield, C. J. (2011) · PLoS Biology · doi:10.1371/journal.pbio.1000604 · Cited by 754
Organization of Actin Networks in Intact Filopodia
Medalia, O., Beck, M., Ecke, M., Weber, I., Neujahr, R., Baumeister, W., & Gerisch, G. (2007) · Current Biology · doi:10.1016/j.cub.2006.11.022 · Cited by 170
Bennett, A. E., Narayan, K., Shi, D., Hartnell, L. M., Gousset, K., He, H., Lowekamp, B. C., Yoo, T. S., Bliss, D., Freed, E. O., et al. (2009) · PLoS Pathogens · doi:10.1371/journal.ppat.1000591 · Cited by 163
Cited by
Ultrastructure and Composition of the Nannochloropsis gaditana Cell Wall
Scholz, M. J., Weiss, T. L., Jinkerson, R. E., Jing, J., Roth, R., Goodenough, U., Posewitz, M. C., & Gerken, H. G. (2014) · Eukaryotic Cell · doi:10.1128/ec.00183-14 · Cited by 436
A repeat protein links Rubisco to form the eukaryotic carbon-concentrating organelle
Mackinder, L. C. M., Meyer, M. T., Mettler-Altmann, T., Chen, V. K., Mitchell, M. C., Caspari, O., Freeman Rosenzweig, E. S., Pallesen, L., Reeves, G., Itakura, A., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522866113 · Cited by 286
Goodson, C., Roth, R., Wang, Z. T., & Goodenough, U. (2011) · Eukaryotic Cell · doi:10.1128/ec.05242-11 · Cited by 254
Defined chromosome structure in the genome-reduced bacterium Mycoplasma pneumoniae
Trussart, M., Yus, E., Martinez, S., Baù, D., Tahara, Y. O., Pengo, T., Widjaja, M., Kretschmer, S., Swoger, J., Djordjevic, S., et al. (2017) · Nature Communications · doi:10.1038/ncomms14665 · Cited by 114
Unkefer, C. J., Sayre, R. T., Magnuson, J. K., Anderson, D. B., Baxter, I., Blaby, I. K., Brown, J. K., Carleton, M., Cattolico, R. A., Dale, T., et al. (2017) · Algal Research · doi:10.1016/j.algal.2016.06.002 · Cited by 90
“Quick-freeze deep-etch electron microscopy (QFDEEM) [85] was used to follow lipid body formation in three strains of special interest”
Metadata
- Authors
- Heuser, J. E.
- Venue
- Microscopy
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-08
- Volume
- 60
- Issue
- suppl_1
- Pages
- S3-S29
- ISSN
- 2050-5698 (ISSN-L)
- 2050-5701
- OpenAlex
- W2125885481
- Cited by
- 74
- References
- 5
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The origins and evolution of freeze-etch electron microscopy. https://app.cochat.ai/papers/10.1093/jmicro/dfr044
- The paper
- Heuser, J. E. (2011). The origins and evolution of freeze-etch electron microscopy. Microscopy. https://doi.org/10.1093/jmicro/dfr044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.