The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The potential for Bayesian compressive sensing to significantly reduce electron dose in high-resolution STEM images
Abstract
The use of high-resolution imaging methods in scanning transmission electron microscopy (STEM) is limited in many cases by the sensitivity of the sample to the beam and the onset of electron beam damage (for example, in the study of organic systems, in tomography and during in situ experiments). To demonstrate that alternative strategies for image acquisition can help alleviate this beam damage issue, here we apply compressive sensing via Bayesian dictionary learning to high-resolution STEM images. These computational algorithms have been applied to a set of images with a reduced number of sampled pixels in the image. For a reduction in the number of pixels down to 5% of the original image, the algorithms can recover the original image from the reduced data set. We show that this approach is valid for both atomic-resolution images and nanometer-resolution studies, such as those that might be used in tomography datasets, by applying the method to images of strontium titanate and zeolites. As STEM images are acquired pixel by pixel while the beam is scanned over the surface of the sample, these postacquisition manipulations of the images can, in principle, be directly implemented as a low-dose acquisition method with no change in the electron optics or the alignment of the microscope itself.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017
Cited by
Plug-and-Play Priors for Bright Field Electron Tomography and Sparse Interpolation
Sreehari, S., Venkatakrishnan, S. V., Wohlberg, B., Buzzard, G. T., Drummy, L. F., Simmons, J. P., & Bouman, C. A. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2599778 · Cited by 300
Hodnik, N., Dehm, G., & Mayrhofer, K. J. J. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00330 · Cited by 256
Metadata
- Authors
- Stevens, A., Yang, H., Carin, L., Arslan, I., & Browning, N. D.
- Venue
- Microscopy
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-10-22
- Volume
- 63
- Issue
- 1
- Pages
- 41-51
- ISSN
- 2050-5698 (ISSN-L)
- 2050-5701
- OpenAlex
- W2142033246
- Cited by
- 158
- References
- 1
- FWCI
- 5.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The potential for Bayesian compressive sensing to significantly reduce electron dose in high-resolution STEM images. https://app.cochat.ai/papers/10.1093/jmicro/dft042
- The paper
- Stevens, A., Yang, H., Carin, L., Arslan, I., & Browning, N. D. (2014). The potential for Bayesian compressive sensing to significantly reduce electron dose in high-resolution STEM images. Microscopy. https://doi.org/10.1093/jmicro/dft042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.