Detection of Hypoxic cells in a Murine Tumour With the Use of the Comet Assay
The DOI matches its Crossref record.
Abstract
BACKGROUND: Hypoxic cells within solid tumors are likely to limit tumor curability by radiation therapy and some chemotherapeutic agents. PURPOSE: To quantify a hypoxic fraction in solid tumors, we developed a method which measures radiation-induced DNA single-strand breaks in individual tumor cells and makes use of the fact that three times more strand breaks are produced in aerobic than in hypoxic cells. METHODS: Immediately after irradiation with doses of 4-20 Gy, SCCVII squamous cell carcinomas growing in C3H mice were removed and cooled, and a single-cell suspension was prepared. These cells were then embedded in agarose, lysed in an alkaline solution, subjected to electrophoresis, and stained with a fluorescent DNA-binding dye. The amount and migration distance of damaged DNA from individual cells were scored by using a fluorescence image processing system, where differentially radio-sensitive aerobic and hypoxic cell populations resulted in bimodal damage distributions. Curve-fitting routines provided quantitative estimates of the fraction of hypoxic cells. RESULTS: After the mice were exposed to 10-20 Gy, the SCCVII tumors (450-600 mg) were shown to have a hypoxic fraction of 18.5% +/- 10.6% (mean +/- SD for 11 tumors), which compares well with the value of 11.6% observed using the paired survival curve method. CONCLUSIONS: Our results indicate that this method, which requires only a few thousand cells, is a rapid and sensitive way to detect hypoxic cells in solid animal tumors. IMPLICATIONS: Estimating hypoxia in accessible human tumors undergoing radiotherapy may be possible if the sensitivity of the method can be improved to allow detection of hypoxic cells after a dose of 2 Gy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The comet assay: a comprehensive review
Fairbairn, D. W., Olive, P. L., & O'Neill, K. L. (1995) · Mutation Research/Reviews in Genetic Toxicology · doi:10.1016/0165-1110(94)00013-3 · Cited by 1,664
Self-citationOpportunities and challenges for use of tumor spheroids as models to test drug delivery and efficacy
Mehta, G., Hsiao, A. Y., Ingram, M., Luker, G. D., & Takayama, S. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.04.045 · Cited by 1,172
“These cell-cell contacts and ensuing communication have been found to influence response of cells to drugs [10, 11].”
Yang, H., Liu, C., Yang, D., Zhang, H., & Xi, Z. (2009) · Journal of Applied Toxicology · doi:10.1002/jat.1385 · Cited by 1,087
Rasey, J. S., Koh, W.-J., Evans, M. L., Peterson, L. M., Lewellen, T. K., Graham, M. M., & Krohn, K. A. (1996) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(96)00325-2 · Cited by 562
Single cell gel electrophoresis assay: methodology and applications
Rojas, E., Lopez, M. C., & Valverde, M. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00313-2 · Cited by 541
Metadata
- Authors
- Olive, P. L., & Durand, R. E.
- Venue
- JNCI Journal of the National Cancer Institute
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-05-06
- Volume
- 84
- Issue
- 9
- Pages
- 707-711
- ISSN
- 0027-8874 (ISSN-L)
- 1460-2105
- OpenAlex
- W2101022542
- Cited by
- 83
- References
- 0
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Hypoxic cells in a Murine Tumour With the Use of the Comet Assay. https://app.cochat.ai/papers/10.1093/jnci/84.9.707
- The paper
- Olive, P. L., & Durand, R. E. (1992). Detection of Hypoxic cells in a Murine Tumour With the Use of the Comet Assay. JNCI Journal of the National Cancer Institute. https://doi.org/10.1093/jnci/84.9.707
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.