CoChat

Physician Predictors of Mammographic Accuracy

Smith-Bindman, R., Chu, P., Miglioretti, D. L., Quale, C., Rosenberg, R. D., Cutter, G., Geller, B., Bacchetti, P., Sickles, E. A., Kerlikowske, K. · 2005 · JNCI Journal of the National Cancer Institute
Cited by 145

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The association between physician experience and the accuracy of screening mammography in community practice is not well studied. We identified characteristics of U.S. physicians associated with the accuracy of screening mammography. METHODS: Data were obtained from the Breast Cancer Surveillance Consortium and the American Medical Association Master File. Unadjusted mammography sensitivity and specificity were calculated according to physician characteristics. We modeled mammography sensitivity and specificity by multivariable logistic regression as a function of patient and physician characteristics. All statistical tests were two-sided. RESULTS: We studied 209 physicians who interpreted 1,220,046 screening mammograms from January 1, 1995, through December 31, 2000, of which 7143 (5.9 per 1000 mammograms) were associated with breast cancer within 12 months of screening. Each physician interpreted a mean of 6011 screening mammograms (95% confidence interval [CI] = 4998 to 6677), including a mean of 34 (95% CI = 28 to 40) from women diagnosed with breast cancer. The mean sensitivity was 77% (range = 29%-97%), and the mean false-positive rate was 10% (range = 1%-29%). After adjustment for the patient characteristics of those whose mammograms they interpreted, physician characteristics were strongly associated with specificity. Higher specificity was associated with at least 25 years (versus less than 10 years) since receipt of a medical degree (for physicians practicing for 25-29 years, odds ratio [OR] = 1.54, 95% CI = 1.14 to 2.08; P = .006), interpretation of 2500-4000 (versus 481-750) screening mammograms annually (OR = 1.30, 95% CI = 1.06 to 1.59; P = .011) and a high focus on screening mammography compared with diagnostic mammography (OR = 1.59, 95% CI = 1.37 to 1.82; P<.001). Higher overall accuracy was associated with more experience and with a higher focus on screening mammography. Compared with physicians who interpret 481-750 mammograms annually and had a low screening focus, physicians who interpret 2500-4000 mammograms annually and had a high screening focus had approximately 50% fewer false-positive examinations and detected a few less cancers. CONCLUSION: Raising the annual volume requirements in the Mammography Quality Standards Act might improve the overall quality of screening mammography in the United States.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jnci/dji060

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 145

Metadata

Authors
Smith-Bindman, R., Chu, P., Miglioretti, D. L., Quale, C., Rosenberg, R. D., Cutter, G., Geller, B., Bacchetti, P., Sickles, E. A., & Kerlikowske, K.
Venue
JNCI Journal of the National Cancer Institute
Published
2005-03-01
Volume
97
Issue
5
Pages
358-367
ISSN
  • 0027-8874 (ISSN-L)
  • 1460-2105
OpenAlex
W2134991575
Cited by
145
References
1
FWCI
5.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Physician Predictors of Mammographic Accuracy. https://app.cochat.ai/papers/10.1093/jnci/dji060
The paper
Smith-Bindman, R., Chu, P., Miglioretti, D. L., Quale, C., Rosenberg, R. D., Cutter, G., Geller, B., Bacchetti, P., Sickles, E. A., & Kerlikowske, K. (2005). Physician Predictors of Mammographic Accuracy. JNCI Journal of the National Cancer Institute. https://doi.org/10.1093/jnci/dji060

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.