Contemporary Diagnostic Imaging Modalities for the Staging and Surveillance of Melanoma Patients: a Meta-analysis
Open accessThe DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Meta-analyses were performed to examine the utility of ultrasonography, computed tomography (CT), positron emission tomography (PET), and a combination of both (PET-CT) for the staging and surveillance of melanoma patients. METHOD: Patient-level data from 74 studies containing 10,528 patients (between January 1, 1990, and June, 30, 2009) were used to derive characteristics of the diagnostic tests used. Meta-analyses were conducted by use of Bayesian bivariate binomial models to estimate sensitivity and specificity. Diagnostic odds ratios [ie, true-positive results/false-negative results)/(false-positive results/true-negative results)] and their 95% credible intervals (CrIs) and positive predictive values were used as indicators of test performance. RESULTS: Among the four imaging methods examined for the staging of regional lymph nodes, ultrasonography had the highest sensitivity (60%, 95% CrI = 33% to 83%), specificity (97%, 95% CrI = 88% to 99%), and diagnostic odds ratio (42, 95% CrI = 8.08 to 249.8). For staging of distant metastases, PET-CT had the highest sensitivity (80%, 95% CrI = 53% to 93%), specificity (87%, 95% CrI = 54% to 97%), and diagnostic odds ratio (25, 95% CrI = 3.58 to 198.7). Similar trends were observed for melanoma surveillance of lymph node involvement, with ultrasonography having the highest sensitivity (96%, 95% CrI = 85% to 99%), specificity (99%, 95% CrI = 95% to 100%), and diagnostic odds ratio (1675, 95% CrI = 226.6 to 15,920). For distant metastases, PET-CT had the highest sensitivity (86%, 95% CrI = 76% to 93%), specificity (91%, 95% CrI = 79% to 97%), and diagnostic odds ratio (67, 95% CrI = 20.42 to 229.7). Positive predictive values were likewise highest for ultrasonography in lymph node staging and for PET-CT in detecting distant metastases. CONCLUSION: Among the compared modalities, ultrasonography was superior for detecting lymph node metastases, and PET-CT was superior for the detection of distant metastases in both the staging and surveillance of melanoma patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
(2017) · Springer eBooks · doi:10.1007/978-3-319-40618-3 · Cited by 17,242
Inference from iterative simulation using multiple sequences
Gelman, A., & Rubin, D. B. (1992) · Statistical Science · doi:10.1214/ss/1177011136 · Cited by 16,627
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Jemal, A., Murray, T., Samuels, A., Ghafoor, A., Ward, E., & Thun, M. J. (2003) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.53.1.5 · Cited by 3,275
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
The diagnostic odds ratio: a single indicator of test performance
Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00177-x · Cited by 2,261 · cited 1×
“0 is expected for tests with no difference detected between disease and nondisease groups (37).”
BackgroundProjected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Basic and Clinical Biostatistics,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00360-0 · Cited by 1,809
Defensive Medicine Among High-Risk Specialist Physicians in a Volatile Malpractice Environment
Studdert, D. M. (2005) · JAMA · doi:10.1001/jama.293.21.2609 · Cited by 1,266
Cited by
Guidelines of care for the management of primary cutaneous melanoma
Swetter, S. M., Tsao, H., Bichakjian, C. K., Curiel-Lewandrowski, C., Elder, D. E., Gershenwald, J. E., Guild, V., Grant-Kels, J. M., Halpern, A. C., Johnson, T. M., et al. (2019) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2018.08.055 · Cited by 727
Self-citationGuidelines of care for the management of primary cutaneous melanoma
Bichakjian, C. K., Halpern, A. C., Johnson, T. M., Foote Hood, A., Grichnik, J. M., Swetter, S. M., Tsao, H., Barbosa, V. H., Chuang, T.-Y., Duvic, M., et al. (2011) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2011.04.031 · Cited by 616
European consensus-based interdisciplinary guideline for melanoma. Part 1: Diagnostics: Update 2022
Garbe, C., Amaral, T., Peris, K., Hauschild, A., Arenberger, P., Basset-Seguin, N., Bastholt, L., Bataille, V., del Marmol, V., Dréno, B., et al. (2022) · European Journal of Cancer · doi:10.1016/j.ejca.2022.03.008 · Cited by 329
Wang, Q.-B., Zhu, H., Liu, H.-L., & Zhang, B. (2012) · Hepatology · doi:10.1002/hep.25610 · Cited by 246
“The inherent association between sensitivity and specificity was modeled in the bivariate normal distribution by assuming random effects.(29,30) If we denote the sensitivity in the ith study by pAi and the specificity by pBi, their logit transforms, lAi and lBi, in the model can be calculated by the following: lAi 1⁄4…”
MethodMalignant Melanoma S3‐Guideline “Diagnosis, Therapy and Follow‐up of Melanoma”
Pflugfelder, A., Kochs, C., Blum, A., Capellaro, M., Czeschik, C., Dettenborn, T., Dill, D., Dippel, E., Eigentler, T., Feyer, P., et al. (2013) · JDDG: Journal der Deutschen Dermatologischen Gesellschaft · doi:10.1111/ddg.12113_suppl · Cited by 239
European consensus-based interdisciplinary guideline for melanoma. Part 1: Diagnostics – Update 2019
Garbe, C., Amaral, T., Peris, K., Hauschild, A., Arenberger, P., Bastholt, L., Bataille, V., del Marmol, V., Dréno, B., Fargnoli, M. C., et al. (2020) · European Journal of Cancer · doi:10.1016/j.ejca.2019.11.014 · Cited by 192
“Ultrasound of the lymph-nodes appears the best method to detect subclinical nodal disease compared to palpation, CT scan, and PET CT [129,130].”
Prediction and monitoring of relapse in stage III melanoma using circulating tumor DNA
Tan, L., Sandhu, S., Lee, R. J., Li, J., Callahan, J., Ftouni, S., Dhomen, N., Middlehurst, P., Wallace, A., Raleigh, J., et al. (2019) · Annals of Oncology · doi:10.1093/annonc/mdz048 · Cited by 186
“In this series, the imaging surveillance regimen used FDGPET/CT more frequently than is generally performed, potentially reducing the lead time for detection of clinical relapse [29, 30] In our study, despite some limitations in the number of serial Months prior to relapse”
MethodOncologic PET/MRI, Part 2: Bone Tumors, Soft-Tissue Tumors, Melanoma, and Lymphoma
Buchbender, C., Heusner, T. A., Lauenstein, T. C., Bockisch, A., & Antoch, G. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.109306 · Cited by 163
“A metaanalysis on the diagnostic performance of different imaging modalities for N-staging in melanoma patients reported a sensitivity and specificity of 60% and 97% for ultrasonography, which was the highest accuracy achieved in comparison with the low values for CT (9% and 92%, respectively), 18F-FDG PET (30% and 96…”
Result
Metadata
- Authors
- Xing, Y., Bronstein, Y., Ross, M. I., Askew, R. L., Lee, J. E., Gershenwald, J. E., Royal, R., & Cormier, J. N.
- Venue
- JNCI Journal of the National Cancer Institute
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-11-16
- Volume
- 103
- Issue
- 2
- Pages
- 129-142
- ISSN
- 0027-8874 (ISSN-L)
- 1460-2105
- OpenAlex
- W2145427665
- Cited by
- 352
- References
- 69
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.