Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 309

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Ultrasound as the Primary Screening Test for Breast Cancer: Analysis From ACRIN 6666

Open access
Berg, Wendie A., Bandos, Andriy I., Mendelson, Ellen B., Lehrer, Daniel, Jong, Roberta A., Pisano, Etta D.·2016·Journal of the National Cancer Institute

Abstract

BACKGROUND: Mammography is not widely available in all countries, and breast cancer incidence is increasing. We considered performance characteristics using ultrasound (US) instead of mammography to screen for breast cancer. METHODS: Two thousand eight hundred nine participants were enrolled at 20 sites in the United States, Canada, and Argentina in American College of Radiology Imaging 6666. Two thousand six hundred sixty-two participants completed three annual screens (7473 examinations) with US and film-screen (n = 4351) or digital (n = 3122) mammography and had biopsy or 12-month follow-up. Cancer detection, recall, and positive predictive values were determined. All statistical tests were two-sided. RESULTS: One hundred ten women had 111 breast cancer events: 89 (80.2%) invasive cancers, median size 12 mm. The number of US screens to detect one cancer was 129 (95% bootstrap confidence interval [CI] = 110 to 156), and for mammography 127 (95% CI = 109 to 152). Cancer detection was comparable for each of US and mammography at 58 of 111 (52.3%) vs 59 of 111 (53.2%, P = .90), with US-detected cancers more likely invasive (53/58, 91.4%, median size 12 mm, range = 2-40 mm), vs mammography at 41 of 59 (69.5%, median size 13 mm, range = 1-55 mm, P < .001). Invasive cancers detected by US were more frequently node-negative, 34 of 53 (64.2%) vs 18 of 41 (43.9%) by mammography (P = .003). For 4814 incidence screens (years 2 and 3), US had higher recall and biopsy rates and lower PPV of biopsy (PPV3) than mammography: The recall rate was 10.7% (n = 515) vs 9.4% (n = 453, P = .03), the biopsy rate was 5.5% (n = 266) vs 2.0% (n = 97, P < .001), and PPV3 was 11.7% (31/266) vs 38.1% (37/97, P < .001). CONCLUSIONS: Cancer detection rate with US is comparable with mammography, with a greater proportion of invasive and node-negative cancers among US detections. False positives are more common with US screening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/jnci/djv367

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 309

Metadata

Authors
Berg, W. A., Bandos, A. I., Mendelson, E. B., Lehrer, D., Jong, R. A., & Pisano, E. D.
Venue
Journal of the National Cancer Institute
Published
2015-12-28
Volume
108
Issue
4
Pages
djv367
ISSN
  • 0027-8874 (ISSN-L)
  • 1460-2105
OpenAlex
W2253584488
Cited by
309
References
22
FWCI
14.98
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound as the Primary Screening Test for Breast Cancer: Analysis From ACRIN 6666. https://app.cochat.ai/papers/10.1093/jnci/djv367
The paper
Berg, W. A., Bandos, A. I., Mendelson, E. B., Lehrer, D., Jong, R. A., & Pisano, E. D. (2016). Ultrasound as the Primary Screening Test for Breast Cancer: Analysis From ACRIN 6666. Journal of the National Cancer Institute. https://doi.org/10.1093/jnci/djv367

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.