CoChat

Automated image analysis of cytokinesis-blocked micronuclei: an adapted protocol and a validated scoring procedure for biomonitoring

Decordier, I., Papine, A., Plas, G., Roesems, S., Vande Loock, K., Moreno-Palomo, J., Cemeli, E., Anderson, D., Fucic, A., Marcos, R., Soussaline, F., Kirsch-Volders, M. · 2008 · Mutagenesis
Cited by 157

The DOI matches its Crossref record.

Abstract

Micronuclei (MN) frequencies in peripheral blood lymphocytes have been used worldwide as a biomarker of chromosomal damage for genotoxicity testing and biomonitoring studies. Automation of MN analysis would provide faster and more reliable results with minimizing subjective MN identification. We developed an automated facility for the scoring of the in vitro MN cytokinesis-block assay for biomonitoring on Giemsa-stained slides, fulfilling the following criteria: applicable to the cytokinesis-block micronucleus methodology, discriminating between mono-, bi- and polynucleated cells, MN scoring according to HUMN scoring criteria, false-negative MN rate <10% and false-positive (FP) MN rate <1%. We first adapted the slide preparation protocol to obtain an optimal cell density and dispersion, which is important for image analysis. We developed specific algorithms starting from the cell as a detection unit. The whole detection and scoring process was separated into two distinct steps: in the first step, the cells and nuclei are detected; then, in the second step, the MN are searched for in the detected cells. Since the rate of FP MN obtained by the automatic analysis was in the range of 0.5-1.5%, an interactive visual validation step was introduced, which is not time consuming and allows quality control. Validation of the automated scoring procedure was undertaken by comparing the results of visual and automated scoring of micronucleated mono- and binucleated cells in human lymphocytes induced by two clastogens (ionizing radiation and methyl methane-sulphonate), two aneugens (nocodazole and carbendazim) and one apoptogen (staurosporine). Although the absolute MN frequencies obtained with automated scoring were lower as compared to those detected by visual scoring, a clear dose response for MNBN frequencies was observed with the automated scoring system, indicating that it is able to produce biologically relevant and reliable results. These observations, together with its ability to detect cells, nuclei and MN in accordance with the HUMN scoring criteria, confirm the usability of the automated MN analysis system for biomonitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/mutage/gen057

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 157

Metadata

Authors
Decordier, I., Papine, A., Plas, G., Roesems, S., Vande Loock, K., Moreno-Palomo, J., Cemeli, E., Anderson, D., Fucic, A., Marcos, R., Soussaline, F., & Kirsch-Volders, M.
Venue
Mutagenesis
Published
2008-09-05
Volume
24
Issue
1
Pages
85-93
ISSN
  • 0267-8357 (ISSN-L)
  • 1464-3804
OpenAlex
W2159328324
Cited by
157
References
0
FWCI
4.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated image analysis of cytokinesis-blocked micronuclei: an adapted protocol and a validated scoring procedure for biomonitoring. https://app.cochat.ai/papers/10.1093/mutage/gen057
The paper
Decordier, I., Papine, A., Plas, G., Roesems, S., Vande Loock, K., Moreno-Palomo, J., Cemeli, E., Anderson, D., Fucic, A., Marcos, R., Soussaline, F., & Kirsch-Volders, M. (2008). Automated image analysis of cytokinesis-blocked micronuclei: an adapted protocol and a validated scoring procedure for biomonitoring. Mutagenesis. https://doi.org/10.1093/mutage/gen057

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.