The DOI matches its Crossref record.
Probing DNA sequences in solution with a monomer-excimer fluorescence color change
Open accessAbstract
The use of a simple fluorescent nucleoside analogue in detection of point mutations by hybridization in solution is described. Pyrene is placed at 3' and 5' ends of a pair of oligodeoxynucleotide probes via a phosphoramidite derivative of deoxyribose with this fluorophore attached at the 1' position, replacing a DNA base. Adjacent binding of dual probes containing this fluorophore to a complementary target sequence results in a pronounced spectral change from blue pyrene monomer emission (lambdamax= 381 398 nm) to green-white excimer emission (lambdamax= 490 nm). Optimization of the relative binding positions of the two probes shows that the greatest spectral change occurs when they bind with partial end overlap. In optimum orientation, the monomer emission band for the probes decreases intensity by as much as a factor of seven and the excimer band increases up to 40-fold on binding a complementary target. Application to the detection of a single-base point mutation in solution is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Pyrene-Based Materials for Organic Electronics
Figueira-Duarte, T. M., & Müllen, K. (2011) · Chemical Reviews · doi:10.1021/cr100428a · Cited by 1,582
Design and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00573 · Cited by 408
Replacing the Nucleobases in DNA with Designer Molecules
Kool, E. T. (2002) · Accounts of Chemical Research · doi:10.1021/ar000183u · Cited by 345
Self-citationTeo, Y. N., & Kool, E. T. (2012) · Chemical Reviews · doi:10.1021/cr100351g · Cited by 327
Self-citationBinary Probes for Nucleic Acid Analysis
Kolpashchikov, D. M. (2010) · Chemical Reviews · doi:10.1021/cr900323b · Cited by 298
Pyrene-Labeled Base-Discriminating Fluorescent DNA Probes for Homogeneous SNP Typing
Okamoto, A., Kanatani, K., & Saito, I. (2004) · Journal of the American Chemical Society · doi:10.1021/ja039625y · Cited by 275
Wegner, S. V., Okesli, A., Chen, P., & He, C. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068342d · Cited by 271
Østergaard, M. E., & Hrdlicka, P. J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15014f · Cited by 256
Metadata
- Authors
- Paris, P. L., Langenhan, J. M., & Kool, E. T.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-08-01
- Volume
- 26
- Issue
- 16
- Pages
- 3789-3793
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2076673017
- Cited by
- 186
- References
- 0
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.