The DOI matches its Crossref record.
Advantages of 2'-O-methyl oligoribonucleotide probes for detecting RNA targets
Open accessAbstract
We have compared various kinetic and melting properties of oligoribonucleotide probes containing 2'-O-methylnucleotides or 2'-deoxynucleotides with regard to their use in assays for the detection of nucleic acid targets. 2'-O-Methyl oligoribonucleotide probes bound to RNA targets faster and with much higher melting temperatures (Tm values) than corresponding 2'-deoxy oligoribonucleotide probes at all lengths tested (8-26 bases). Tm values of both probes increased with length up to approximately 19 bases, with maximal differences in Tm between 2'-O-methyl and 2'-deoxy oligoribonucleotide probes observed at lengths of 16 bases or less. In contrast to RNA targets, 2'-O-methyl oligoribonucleotide probes bound more slowly and with the same Tm to DNA targets as corresponding 2'-deoxy oligoribonucleotide probes. Because of their greatly enhanced Tm when bound to RNA, 2'-O-methyl oligoribonucleotide probes can efficiently bind to double-stranded regions of structured RNA molecules. A 17 base 2'-O-methyl oligoribonucleotide probe was able to bind a double-stranded region of rRNA whereas the same 17 base 2'- deoxy oligoribonucleotide probe did not. Due to their enhanced Tm when bound to RNA targets, shorter 2'-O-methyl oligoribonucleotide probes can be used in assays in place of longer 2'-deoxy oligoribonucleotide probes, resulting in enhanced discrimination between matched and mismatched RNA targets. A 12 base 2'-O-methyl oligoribonucleotide probe had the same Tm as a 19 base 2'-deoxy oligoribonucleotide probe when bound to a matched RNA target but exhibited a much larger decrease in Tm than the 2'-deoxy oligoribonucleotide probe when bound to an RNA target containing either 1 or 2 mismatched bases. The increased Tm, faster kinetics of hybridization, ability to bind to structured targets and increased specificity of 2'-O-methyl oligoribonucleotide probes render them superior to corresponding 2'-deoxy oligoribonucleotides for use in assays that detect RNA targets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DNA Microarray Technology: Devices, Systems, and Applications
Heller, M. J. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153438 · Cited by 1,068
Therapeutic targeting of microRNAs: current status and future challenges
Li, Z., & Rana, T. M. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4359 · Cited by 1,033
siRNA function in RNAi: A chemical modification analysis
CHIU, Y.-L., & RANA, T. M. (2003) · RNA · doi:10.1261/rna.5103703 · Cited by 860
Sequence-specific inhibition of microRNA- and siRNA-induced RNA silencing
MEISTER, G., LANDTHALER, M., DORSETT, Y., & TUSCHL, T. (2004) · RNA · doi:10.1261/rna.5235104 · Cited by 621
Designing Chemically Modified Oligonucleotides for Targeted Gene Silencing
Deleavey, G. F., & Damha, M. J. (2012) · Chemistry & Biology · doi:10.1016/j.chembiol.2012.07.011 · Cited by 589
Metadata
- Authors
- Majlessi, M.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-05-01
- Volume
- 26
- Issue
- 9
- Pages
- 2224-2229
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2084120903
- Cited by
- 213
- References
- 0
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Advantages of 2'-O-methyl oligoribonucleotide probes for detecting RNA targets. https://app.cochat.ai/papers/10.1093/nar/26.9.2224
- The paper
- Majlessi, M. (1998). Advantages of 2'-O-methyl oligoribonucleotide probes for detecting RNA targets. Nucleic Acids Research. https://doi.org/10.1093/nar/26.9.2224
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.