The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Absolute mRNA concentrations from sequence-specific calibration of oligonucleotide arrays
Open accessAbstract
Oligonucleotide microarrays are based on the hybridization of labeled mRNA molecules to short length oligonucleotide probes on a glass surface. Two effects have been shown to affect the raw data: the sequence dependence of the probe hybridization properties and the chemical saturation resulting from surface adsorption processes. We address both issues simultaneously using a physically motivated hybridization model. Based on publicly available calibration data sets, we show that Langmuir adsorption accurately describes GeneChip hybridization, with model parameters that we predict from the sequence composition of the probes. Because these parameters have physical units, we are able to estimate absolute mRNA concentrations in picomolar. Additionally, by accounting for chemical saturation, we substantially reduce the compressive bias of differential expression estimates that normally occurs toward high concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Model-based analysis of oligonucleotide arrays: Expression index computation and outlier detection.
Li, C., & Wong, W. H. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.1.31 · Cited by 3,133
Cited by
A high-resolution map of transcription in the yeast genome
David, L., Huber, W., Granovskaia, M., Toedling, J., Palm, C. J., Bofkin, L., Jones, T., Davis, R. W., & Steinmetz, L. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601091103 · Cited by 697
Reliability and reproducibility issues in DNA microarray measurements
DRAGHICI, S., KHATRI, P., EKLUND, A., & SZALLASI, Z. (2006) · Trends in Genetics · doi:10.1016/j.tig.2005.12.005 · Cited by 590
High-resolution mapping of copy-number alterations with massively parallel sequencing
Chiang, D. Y., Getz, G., Jaffe, D. B., O'Kelly, M. J. T., Zhao, X., Carter, S. L., Russ, C., Nusbaum, C., Meyerson, M., & Lander, E. S. (2009) · Nature Methods · doi:10.1038/nmeth.1276 · Cited by 510
Model-based analysis of tiling-arrays for ChIP-chip
Johnson, W. E., Li, W., Meyer, C. A., Gottardo, R., Carroll, J. S., Brown, M., & Liu, X. S. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601180103 · Cited by 429
Applications of DNA tiling arrays for whole-genome analysis
Mockler, T. C., & Ecker, J. R. (2005) · Genomics · doi:10.1016/j.ygeno.2004.10.005 · Cited by 400
Metadata
- Authors
- Hekstra, D.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-04-01
- Volume
- 31
- Issue
- 7
- Pages
- 1962-1968
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2127299993
- Cited by
- 165
- References
- 1
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Absolute mRNA concentrations from sequence-specific calibration of oligonucleotide arrays. https://app.cochat.ai/papers/10.1093/nar/gkg283
- The paper
- Hekstra, D. (2003). Absolute mRNA concentrations from sequence-specific calibration of oligonucleotide arrays. Nucleic Acids Research. https://doi.org/10.1093/nar/gkg283
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.