A novel fluorescence-based assay for the rapid detection and quantification of cellular deoxyribonucleoside triphosphates
Open accessThe DOI matches its Crossref record.
Abstract
Current methods for measuring deoxyribonucleoside triphosphates (dNTPs) employ reagent and labor-intensive assays utilizing radioisotopes in DNA polymerase-based assays and/or chromatography-based approaches. We have developed a rapid and sensitive 96-well fluorescence-based assay to quantify cellular dNTPs utilizing a standard real-time PCR thermocycler. This assay relies on the principle that incorporation of a limiting dNTP is required for primer-extension and Taq polymerase-mediated 5-3' exonuclease hydrolysis of a dual-quenched fluorophore-labeled probe resulting in fluorescence. The concentration of limiting dNTP is directly proportional to the fluorescence generated. The assay demonstrated excellent linearity (R(2) > 0.99) and can be modified to detect between ∼0.5 and 100 pmol of dNTP. The limits of detection (LOD) and quantification (LOQ) for all dNTPs were defined as <0.77 and <1.3 pmol, respectively. The intra-assay and inter-assay variation coefficients were determined to be <4.6% and <10%, respectively with an accuracy of 100 ± 15% for all dNTPs. The assay quantified intracellular dNTPs with similar results obtained from a validated LC-MS/MS approach and successfully measured quantitative differences in dNTP pools in human cancer cells treated with inhibitors of thymidylate metabolism. This assay has important application in research that investigates the influence of pathological conditions or pharmacological agents on dNTP biosynthesis and regulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
HIV-1 restriction factor SAMHD1 is a deoxynucleoside triphosphate triphosphohydrolase
Goldstone, D. C., Ennis-Adeniran, V., Hedden, J. J., Groom, H. C. T., Rice, G. I., Christodoulou, E., Walker, P. A., Kelly, G., Haire, L. F., Yap, M. W., et al. (2011) · Nature · doi:10.1038/nature10623 · Cited by 831
Purhonen, J., Banerjee, R., McDonald, A. E., Fellman, V., & Kallijärvi, J. (2020) · Nucleic Acids Research · doi:10.1093/nar/gkaa516 · Cited by 657
“For the fluorochrome-quencher-probe -based polymerase assay for dNTPs, we followed the published protocol (7) with minor modifications.”
BackgroundMethodResultInfluentialFatty acid carbon is essential for dNTP synthesis in endothelial cells
Schoors, S., Bruning, U., Missiaen, R., Queiroz, K. C. S., Borgers, G., Elia, I., Zecchin, A., Cantelmo, A. R., Christen, S., Goveia, J., et al. (2015) · Nature · doi:10.1038/nature14362 · Cited by 646
DNA-Mediated Homogeneous Binding Assays for Nucleic Acids and Proteins
Zhang, H., Li, F., Dever, B., Li, X.-F., & Le, X. C. (2013) · Chemical Reviews · doi:10.1021/cr300340p · Cited by 415
Aird, K. M., Zhang, G., Li, H., Tu, Z., Bitler, B. G., Garipov, A., Wu, H., Wei, Z., Wagner, S. N., Herlyn, M., et al. (2013) · Cell Reports · doi:10.1016/j.celrep.2013.03.004 · Cited by 285
“dNTPs concentration was measured as previously described (Wilson et al., 2011).”
Method
Metadata
- Authors
- Wilson, P. M., LaBonte, M. J., Russell, J., Louie, S., Ghobrial, A. A., & Ladner, R. D.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-05-14
- Volume
- 39
- Issue
- 17
- Pages
- e112-e112
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W4240753862
- Cited by
- 89
- References
- 0
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel fluorescence-based assay for the rapid detection and quantification of cellular deoxyribonucleoside triphosphates. https://app.cochat.ai/papers/10.1093/nar/gkr350
- The paper
- Wilson, P. M., LaBonte, M. J., Russell, J., Louie, S., Ghobrial, A. A., & Ladner, R. D. (2011). A novel fluorescence-based assay for the rapid detection and quantification of cellular deoxyribonucleoside triphosphates. Nucleic Acids Research. https://doi.org/10.1093/nar/gkr350
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.