The DOI matches its Crossref record.
Non-invasive evaluation of vessels by duplex sonography prior to construction of arteriovenous fistulas for haemodialysis
Abstract
PURPOSE: The prospective study was aimed at estimating the value of duplex sonography for imaging arteries before arteriovenous fistula (AVF) construction and of evaluating the influence of this method on the outcome of fistula construction. METHODS: A total of 35 patients with end stage renal disease were examined by duplex sonography (DS) before AVF construction, and 27 of them with patent AVF were examined 1, 7 and 21 days after the operation. Filling artery flow was evaluated at 8 and 12 weeks. All AVFs were constructed on the forearm using native veins. Direct measurements of the arterial internal diameter during the operation were also performed. RESULTS: The mean internal diameter of the arteries (IDA) detected by sonography 2.3 +/- 0.62 mm, with a direct measurement of 2.1 +/- 0.52 mm (mean +/- SD). The correlation coefficient of DS IDA with direct measurement IDA was 0.86. In group A (IDA < or = 1.5 mm), immediate patency of the AVF was present in 45% (5/11), and in group B (IDA > 1.5 mm) 92% (22/24) (P < 0.001). Before the construction, the mean volume flow through the radial arteries was 22 +/- 6.8 ml/min in group A and in group B 46 +/- 6.3 ml/min (P < 0.01). If there was conversion of high-resistance triphasic Doppler flow signal to low-resistance biphasic flow signal after release of a fist (group D), the AVF was patent in 95% (21/22), compared with a 46% (6/13) rate of patency in the group without such a response (group C). In 27 patients with patent AVF fistula, arterial volume flow the first day after construction was 138.1 +/- 10.1 ml/min in group A and 184.2 +/- 12.6 ml/min in group B. After 1 week, the volume flow was 169 +/- 11.1 ml/min and 202.4 +/- 13.5 ml/min, respectively. After 3 weeks the arterial flow was 274.4 +/- 17.3 ml/min, and 366.2 +/- 39.6 ml/min, respectively. After 12 weeks, the arterial flow was 438.5 +/- 87.7 ml/min in group A, and 561.8 +/- 131.3 ml/min in group B. The patency rate after 12 weeks was 36% in group A and 83% in group B. CONCLUSIONS: Duplex sonography could be a useful non-invasive method to evaluate arterial vessels prior to AVF construction. The relevant parameters measured by duplex sonography to evaluate the potential patency of the AVF are the arterial internal diameter and changes in the arterial Doppler flow signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Native arteriovenous fistula: Preoperative evaluation
Malovrh, M. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.33394 · Cited by 351
Self-citationGuía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Metadata
- Authors
- Malovrh, M.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 1998-01-01
- Volume
- 13
- Issue
- 1
- Pages
- 125-129
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W2151306866
- Cited by
- 196
- References
- 0
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive evaluation of vessels by duplex sonography prior to construction of arteriovenous fistulas for haemodialysis. https://app.cochat.ai/papers/10.1093/ndt/13.1.125
- The paper
- Malovrh, M. (1998). Non-invasive evaluation of vessels by duplex sonography prior to construction of arteriovenous fistulas for haemodialysis. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/13.1.125
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.