Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record.

GFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe

Brandstrom, E · 1998 · Nephrology Dialysis Transplantation

Abstract

BACKGROUND: The aim of the present study was to compare the most commonly used GFR markers for clearance measurements, 51Cr-EDTA and iohexol, using two different methods for iohexol analysis, HPLC and X-ray fluorescence, referring both to the multiple-sample and single-sample calculations, using 51Cr-EDTA as the reference method. METHODS: Forty-nine patients with an estimated GFR >40 ml/min were included. 51Cr-EDTA and iohexol were injected simultaneously and blood samples were taken 150, 195 and 240 min after injection of the respective marker. RESULTS: The multiple-point clearances, determined from HPLC and X-ray fluorescence, compared to 51Cr-EDTA correlated highly (r=0.92 and 0.95 respectively). The results from single-point clearance comparison, iohexol measured by HPLC vs 51Cr-EDTA, yielded a correlation of r=0.91, while single-point clearance from iohexol, analysed by X-ray fluorescence, obtained a correlation of 0.93 and an intercept statistically different from origo. CONCLUSIONS: Iohexol and 51Cr-EDTA are comparable as GFR markers for multiple-point clearance measurements. The single-sample method for GFR >40 ml/min can be used with a high accuracy. The precision and accuracy of X-ray fluorescence analysis of low concentrations of iohexol were less than those of HPLC. Care should therefore be taken when using X-ray fluorescence that the injected dose of iohexol should result in a plasma concentration level of iodine of at least 0.06 mg/ml at the time of blood sampling.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/13.5.1176

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Brandstrom, E.
Venue
Nephrology Dialysis Transplantation
Published
1998-05-01
Volume
13
Issue
5
Pages
1176-1182
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2164655181
Cited by
161
References
0
FWCI
1.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: GFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe. https://app.cochat.ai/papers/10.1093/ndt/13.5.1176
The paper
Brandstrom, E. (1998). GFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/13.5.1176

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.