What is hypertension in chronic haemodialysis? The role of interdialytic blood pressure monitoring
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Hypertension in chronic haemodialysis patients contributes significantly to morbidity and mortality. Treatment decisions are usually based on predialysis readings, which may not accurately reflect control during the interdialytic period. METHODS: We studied 40 randomly selected subjects on haemodialysis and compared readings by different methods at set times during the dialysis session with the 48-h interdialytic ambulatory readings. Conventional sphygmomanometer, automated Dinamap and Tm 2421(A&D) ambulatory monitor were used for BP measurements. RESULTS: Conventional sphygmomanometry and self measured automatic readings (Dinamap) were highly correlated (systolic r=0.93, P<0.001; diastolic r=0.90, P<0.001). Mean blood pressure on arrival ((PreC(0)) 158 mmHg systolic, 80 mmHg diastolic and 106 mmHg mean) significantly overestimated the mean ambulatory reading during the 6 h prior to attendance ((preAm(6h)) systolic 147 (P<0.01), diastolic 75 (P<0.01), mean 99 (P<0.01)). Fifteen patients (41%) demonstrated a marked difference (>20/10 mmHg) between the PreC(0) and preAm(6h) (white-coat effect) persisting in seven patients (19%) after a period of rest 10 min predialysis (preC(10)) and present even in self-recorded Dinamap readings. There was a significant negative relationship between the systolic rise and the number of months on dialysis (P<0.05). Mean ambulatory BP on interdialytic day 2 was significantly greater than on day 1 whereas the awake-sleep differences were less on day 2 than day 1, both perhaps reflecting differences in volume status. The 20 min post-dialysis measurement (PoC(20)) for systolic, diastolic, and mean, unlike predialysis (PreC(0) and preC(10)), onset (onC) and end of dialysis readings (enC) did not differ significantly from 48 h interdialytic means. CONCLUSIONS: The best representation of interdialytic pressure was the 20-min post-dialysis reading. Walk-in predialysis pressures overestimate mean interdialytic pressures due to a high incidence of white-coat effect, which shows some habituation with time on dialysis. Ambulatory monitoring has a role in evaluating persistent poor blood pressure control in haemodialysis patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Cited by
Agarwal, R., Bills, J. E., Hecht, T. J. W., & Light, R. P. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.160911 · Cited by 430
Davies, S. J., & Davenport, A. (2014) · Kidney International · doi:10.1038/ki.2014.207 · Cited by 314
Agarwal, R., Peixoto, A. J., Santos, S. F. F., & Zoccali, C. (2006) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.01891105 · Cited by 245
Assessment and Management of Hypertension in Patients on Dialysis
Agarwal, R., Flynn, J., Pogue, V., Rahman, M., Reisin, E., & Weir, M. R. (2014) · Journal of the American Society of Nephrology · doi:10.1681/asn.2013060601 · Cited by 190
Home blood pressure monitoring improves the diagnosis of hypertension in hemodialysis patients
Agarwal, R., Andersen, M. J., Bishu, K., & Saha, C. (2006) · Kidney International · doi:10.1038/sj.ki.5000145 · Cited by 175
Metadata
- Authors
- Mitra, S., Chandna, S. M., & Farrington, K.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-12-01
- Volume
- 14
- Issue
- 12
- Pages
- 2915-2921
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W2124619474
- Cited by
- 66
- References
- 1
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.