The DOI matches its Crossref record.
Outcome and complications of temporary haemodialysis catheters
Abstract
BACKGROUND: The use of temporary haemodialysis catheters is often complicated by mechanical or infectious complications. Risk factors for these complications and optimal management to reduce their incidence are largely unknown. METHODS: We conducted a prospective study of 105 haemodialysis catheters (79 subclavian, 26 jugular) inserted in 52 patients in order to identify patient outcomes and to analyse the effect of patient and catheter factors on the incidence of infectious complications by multivariate analysis. RESULTS: Fifty-nine per cent of catheters were removed for a suspected complication. Catheter-related bacteraemia (CRB) was diagnosed in 17 catheters (16%), giving a bacteraemia rate of 6.5 episodes per 1000 catheter days. Subgroup analysis revealed a higher risk of CRB with the use of the internal jugular compared with the subclavian site (hazard ratio 3.97, P=0.02). Age, diabetes or catheter exchange over a guidewire did not alter the risk of CRB. The cumulative risk of developing CRB increased in a linear fashion as the period of catheterization increased. Exit-site infection was the cause for removal in eight catheters (8%). Although the number of exit-site infections was small, the risk of exit-site infection was increased in diabetic patients (hazard ratio 10, P=0.03) and the jugular position (hazard ratio 6.5, P=0.01) but not by age or catheter exchange over a guidewire. Staphylococcus aureus and coagulase-negative staphylococcus accounted for all proven episodes of CRB. Exit-site infection was associated with a mixture of Gram-positive and Gram-negative organisms. CONCLUSIONS: Temporary haemodialysis catheters have a high failure rate associated with a significant rate of complications. Use of the internal jugular site is associated with a significantly higher risk of infectious complications and methods to reduce this risk should be considered if this site is used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Guidelines for the management of intravascular catheter-related infections
Mermel, L. A., Farr, B. M., Sherertz, R. J., Raad, I. I., O'Grady, N., Harris, J. S., & Craven, D. E. (2001) · Clinical Infectious Diseases · doi:10.1086/320001 · Cited by 1,449
Infectious complications of the hemodialysis access
Nassar, G. M., & Ayus, J. C. (2001) · Kidney International · doi:10.1046/j.1523-1755.2001.00765.x · Cited by 378
Weijmer, M. C., van den Dorpel, M. A., Van de Ven, P. J. G., ter Wee, P. M., van Geelen, J. A. C. A., Groeneveld, J. O., van Jaarsveld, B. C., Koopmans, M. G., le Poole, C. Y., Schrander-Van der Meer, A. M., et al. (2005) · Journal of the American Society of Nephrology · doi:10.1681/asn.2004100870 · Cited by 302
Oliver, M. J., Callery, S. M., Thorpe, K. E., Schwab, S. J., & Churchill, D. N. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00439.x · Cited by 269
Metadata
- Authors
- Kairaitis, L.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-07-01
- Volume
- 14
- Issue
- 7
- Pages
- 1710-1714
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W2133474915
- Cited by
- 174
- References
- 0
- FWCI
- 13.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Outcome and complications of temporary haemodialysis catheters. https://app.cochat.ai/papers/10.1093/ndt/14.7.1710
- The paper
- Kairaitis, L. (1999). Outcome and complications of temporary haemodialysis catheters. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/14.7.1710
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.