The DOI matches its Crossref record.
The function of permanent vascular access
Abstract
BACKGROUND: Complications arising from vascular access (VA) are major causes of morbidity in patients on renal replacement therapy (RRT). They contribute to frustration of health care providers and to high medical cost. To prevent failures in the future it will be helpful to identify the factors that are related to VA malfunction. METHODS: In a retrospective analysis we analysed the types, duration and primary rate of patency of 1033 permanent vascular accesses in 544 consecutive patients established during a 13-year period in a tertiary care hospital. Patient characteristics, incidence, and risk factors related to VA failure were registered. In addition, VA outcomes in patients who started haemodialysis with a catheter and in whom initial VA failure occurred were analysed separately. RESULTS: Forty-five per cent of patients required a central catheter at the start of HD, but 92% of them were being dialysed with an a-v fistula at the last observation. The total number of complications was 0.24 episodes per patient per year at risk and the rate of thrombosis 0.1. A total of 52% of patients were dialysed throughout the observation period with their initial a-v fistula; 9.3% had more than three episodes of VA failure. The radiocephalic a-v fistula was the VA with the best median duration, exceeding 7 years, but also the type that had the highest initial failure rate, i.e. 25% of patients and 13% of the events. The brachiocephalic a-v fistula was the second most frequent type of VA, with a median duration of function of 3.6 years, in contrast to the humerobasilic a-v fistula, which exceeded 5 years. Average patency of the different types of grafts did not exceed 1 year, with the exception of the autologous saphenous graft with a median duration of function of 1.4 years. Patients with glomerulonephritis had the best function rates for their VA, the median exceeding the duration of the study, whereas in half of the diabetic patients it was less than 1 year. The duration of patency of the VA was twice in patients below age 65 years and in elderly males compared to elderly females. Patients who started HD with a catheter, as well as those with initial VA failure, had a higher rate of VA failure in the subsequent course on RRT. CONCLUSION: The radiocephalic and the humerobasilic a-v fistulae are the two types of VA with the longest duration of function, although a high rate of initial failure is seen with the radiocephalic a-v fistula. Age, female gender, presence of diabetic nephropathy, start of dialysis with a catheter, and failure to wait for initial maturation of the VA are risk factors, and account for the majority of VA failures during RRT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Native arteriovenous fistula: Preoperative evaluation
Malovrh, M. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.33394 · Cited by 351
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Metadata
- Authors
- Rodriguez, J. A., Armadans, L., Ferrer, E., Olmos, A., Codina, S., Bartolomé, J., Borrellas, J., & Piera, L.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-03-01
- Volume
- 15
- Issue
- 3
- Pages
- 402-408
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W2153900910
- Cited by
- 165
- References
- 0
- FWCI
- 16.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The function of permanent vascular access. https://app.cochat.ai/papers/10.1093/ndt/15.3.402
- The paper
- Rodriguez, J. A., Armadans, L., Ferrer, E., Olmos, A., Codina, S., Bartolomé, J., Borrellas, J., & Piera, L. (2000). The function of permanent vascular access. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/15.3.402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.