CoChat

The variability and accurate assessment of microinflammation in haemodialysis patients

Open access
Tsirpanlis, G., Bagos, P., Ioannou, D., Bleta, A., Marinou, I., Lagouranis, A., Chatzipanagiotou, S., Nicolaou, C. · 2004 · Nephrology Dialysis Transplantation
Cited by 66

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Systemic microinflammation is correlated with atherosclerosis. It needs a reliable assessment. This study explores the temporal variations of three inflammatory indexes [C-reactive protein (CRP), serum amyloid A (SAA) and interleukin-6 (IL-6)] in a period free of clinical events and tests the reliability of their multiple measurements for the assessment of microinflammation in haemodialysis (HD) patients, a population at high risk of atherosclerotic cardiovascular disease. METHODS: For 4 months, serum CRP, SAA and IL-6 were measured in 29 HD patients during the weeks they were free of inflammatory clinical events (> or =12 measurements for each index in every patient). The components of the variance as well as the reliability of two to five measurements for each index, aimed at assessing microinflammation precisely, were computed. RESULTS: The median (interquartile range) of CRP was 2.3 (0.9-4.9) mg/l, of SAA 3.7 (2.1-9.3) mg/l and of IL-6 4.4 (2.2-7.7) pg/ml. Patients were approximately equally distributed between three groups of low, intermediate and high variability for each index. The contribution of intraindividual (biological) variation to the total of variance was 71.3%, 69.3% and 86.7% for CRP, SAA and IL-6, respectively (higher than in all other similar studies in healthy populations). Using two measurements, the estimated reliability was 57-68% for CRP in two-thirds of the patients (comparable with that found in healthy subjects) and 57% for SAA and IL-6 in only one-third of the patients. Increasing the number of measurements up to five did not change the reliability. CONCLUSIONS: Individual factors significantly influence the levels of inflammatory indexes in HD patients in periods free of inflammatory clinical events. The mean of two weekly CRP measurements, but not of SAA or IL-6, seems to assess microinflammation in most patients with a sufficient reliability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfg486

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 66

Metadata

Authors
Tsirpanlis, G., Bagos, P., Ioannou, D., Bleta, A., Marinou, I., Lagouranis, A., Chatzipanagiotou, S., & Nicolaou, C.
Venue
Nephrology Dialysis Transplantation
Published
2004-01-01
Volume
19
Issue
1
Pages
150-157
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2127576356
Cited by
66
References
1
FWCI
4.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The variability and accurate assessment of microinflammation in haemodialysis patients. https://app.cochat.ai/papers/10.1093/ndt/gfg486
The paper
Tsirpanlis, G., Bagos, P., Ioannou, D., Bleta, A., Marinou, I., Lagouranis, A., Chatzipanagiotou, S., & Nicolaou, C. (2004). The variability and accurate assessment of microinflammation in haemodialysis patients. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfg486

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.