Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 190

The DOI matches its Crossref record.

Compared to tunnelled cuffed haemodialysis catheters, temporary untunnelled catheters are associated with more complications already within 2 weeks of use

Weijmer, M. C., Vervloet, M. G., ter Wee, P. M. · 2004 · Nephrology Dialysis Transplantation

Abstract

BACKGROUND: Comparison of outcome of untunnelled catheters (UCs) and tunnelled cuffed catheters (TCCs) is difficult because they are usually used for different patients and conditions. The aim of the present study is to compare the outcome of TCCs with UCs limiting as much as possible the influence of confounding factors. The second purpose was to see whether our results support the time recommendations for maximum use of UCs outlined in the NKF-DOQI guidelines. METHODS: Catheter and patient characteristics, catheter-related complications and all cultures taken from haemodialysis catheters inserted during a 3 year period were collected. RESULTS: We analysed the outcome of 272 catheters (149 patients, 11 612 catheter-days, 37 TCC and 235 UC). Patients with an UC suffered more often from acute renal failure (40 vs 8% for TCCs, P<0.001), their hospitalization rates were higher (54 vs 14%, P<0.001) and coumarins were used less (11 vs 27%, P<0.01). Rates of preliminary removal were 1.8 per 1000 catheter-days for TCCs, 35.3 for untunnelled femoral catheters (UFCs) and 17.1 for untunnelled jugular catheters (UJCs). Infection rates were 2.9 per 1000 catheter-days for TCCs, 15.6 for UJCs and 20.2 for UFCs. Hospitalization was an independent risk factor for an adverse outcome and more apparent in patients with an UC. After correction for patient differences, the strongest risk factor for preliminary removal (RR 9.69, P<0.001) and infection (RR 3.76, P<0.001) was having an UC inserted. Already, within 2 weeks actuarial and infection-free survival were better for TCCs (P<0.05 vs all separate groups). CONCLUSIONS: According to our results, a TCC should be used whenever it can be foreseen that a haemodialysis catheter is needed for more than 14 days.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfg581

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 190

Metadata

Authors
Weijmer, M. C., Vervloet, M. G., & ter Wee, P. M.
Venue
Nephrology Dialysis Transplantation
Published
2004-02-06
Volume
19
Issue
3
Pages
670-677
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2077944225
Cited by
190
References
0
FWCI
8.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compared to tunnelled cuffed haemodialysis catheters, temporary untunnelled catheters are associated with more complications already within 2 weeks of use. https://app.cochat.ai/papers/10.1093/ndt/gfg581
The paper
Weijmer, M. C., Vervloet, M. G., & ter Wee, P. M. (2004). Compared to tunnelled cuffed haemodialysis catheters, temporary untunnelled catheters are associated with more complications already within 2 weeks of use. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfg581

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.