Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record.

Sustained low-efficiency daily diafiltration (SLEDD-f) for critically ill patients requiring renal replacement therapy: towards an adequate therapy

Open access
Marshall, M. R., Ma, T., Galler, D., Rankin, A. P. N., Williams, A. B.·2004·Nephrology Dialysis Transplantation

Abstract

BACKGROUND: Sustained low-efficiency daily dialysis (SLEDD) is an increasingly popular renal replacement therapy for intensive care unit (ICU) patients. SLEDD has been previously reported to provide good solute control and haemodynamic stability. However, continuous renal replacement therapy (CRRT) is considered superior by many ICU practitioners, due first to the large amounts of convective clearance achieved and second to the ability to deliver treatment independently of nephrology services. We report on a program of sustained low-efficiency daily diafiltration (SLEDD-f) delivered autonomously by ICU nursing personnel, and benchmark solute clearance data with recently published reports that have provided dose-outcome relationships for renal replacement therapy in this population. METHODS: SLEDD-f treatments were delivered using countercurrent dialysate flow at 200 ml/min and on-line haemofiltration at 100 ml/min for 8 h on a daily or at least alternate day basis. All aspects of SLEDD-f were managed by ICU nursing personnel. Clinical parameters, patient outcomes and solute levels were monitored. Kt/V, corrected equivalent renal urea clearance (EKRc) and theoretical Kt/V(B12) were calculated. RESULTS: Fifty-six SLEDD-f treatments in 24 critically ill acute renal failure patients were studied. There were no episodes of intradialytic hypotension or other complications. Observed hospital mortality was 46%, not significantly different from the expected mortality as determined from the APACHE II illness severity scoring system. Electrolyte control was excellent. Kt/V per completed treatment was 1.43+/-0.28 (0.96-2.0). Kt/V(B12) per completed treatment was 1.02+/-0.21 (0.6-1.38). EKRc for patients was 35.7+/-6.4 ml/min (25.0-48.2). CONCLUSION: SLEDD-f provides stable renal replacement therapy and good clinical outcomes. Logistic elements of SLEDD-f delivery by ICU nursing personnel are satisfactory. Small solute clearance is adequate by available standards for CRRT and intermittent haemodialysis, and larger solute clearance considerable. SLEDD-f is a viable alternative to CRRT in this setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfg625

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 181

Metadata

Authors
Marshall, M. R., Ma, T., Galler, D., Rankin, A. P. N., & Williams, A. B.
Venue
Nephrology Dialysis Transplantation
Published
2004-03-18
Volume
19
Issue
4
Pages
877-884
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2171696781
Cited by
181
References
0
FWCI
6.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sustained low-efficiency daily diafiltration (SLEDD-f) for critically ill patients requiring renal replacement therapy: towards an adequate therapy. https://app.cochat.ai/papers/10.1093/ndt/gfg625
The paper
Marshall, M. R., Ma, T., Galler, D., Rankin, A. P. N., & Williams, A. B. (2004). Sustained low-efficiency daily diafiltration (SLEDD-f) for critically ill patients requiring renal replacement therapy: towards an adequate therapy. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfg625

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.