The DOI matches its Crossref record.
Colour Doppler ultrasound in dialysis access
Abstract
The native arteriovenous fistula (AVF) at the wrist [1] is generally accepted as the vascular access of choice in haemodialysis patients due to its low complication and high patency rates [2]. However, with an increasing number of elderly patients and patients with co-morbid conditions such as vascular disease and diabetes mellitus in the haemodialysis population, the creation and maintenance of a patent and well-functioning AVF has become a real challenge to nephrologists and vascular surgeons [3]. The DOQI guidelines state that creation of a primary AVF is possible in only 50% of the patients [4]. Therefore, in the US, synthetic polytetrafluoroethylene (PTFE) grafts are still the predominant form of permanent vascular access [5,6], despite the well known poorer outcome compared to AVFs [4,6,7]. To further increase the use of native AVFs, especially in the co-morbid patient group, a thorough preoperative evaluation with colour Doppler ultrasound (CDU) and mapping of the arterial and venous vascular system allows the placement of an AVF in a higher proportion of patients [8,9] and to achieve a better cumulative patency rate of fistulas [10]. After creation of access, periodic monitoring is recommended, since early detection of access dysfunction and subsequent intervention may help to reduce the rate of access failure [11,12]. Although angiography has been considered as the gold standard for imaging of vascular access abnormalities, duplex ultrasound may be superior in some aspects since it provides information both on the morphology and on the function of vascular access. In addition, CDU offers the advantage of a non-invasive bedside procedure with lower costs and with no need for radiocontrast. The aim of this article is to provide an update on CDU and to give some new information on preoperative evaluation and routine monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hofstra, L., Tordoir, J. H. M., Kitslaar, P. J. E. H. M., Hoeks, A. P. G., & Daemen, M. J. A. P. (1996) · Circulation · doi:10.1161/01.cir.94.6.1283 · Cited by 1,603
Schmidli, J., Widmer, M. K., Basile, C., de Donato, G., Gallieni, M., Gibbons, C. P., Haage, P., Hamilton, G., Hedin, U., Kamper, L., et al. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.02.001 · Cited by 878
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
Metadata
- Authors
- Wiese, P., & Nonnast-Daniel, B.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-06-15
- Volume
- 19
- Issue
- 8
- Pages
- 1956-1963
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W2095724681
- Cited by
- 161
- References
- 0
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Colour Doppler ultrasound in dialysis access. https://app.cochat.ai/papers/10.1093/ndt/gfh244
- The paper
- Wiese, P., & Nonnast-Daniel, B. (2004). Colour Doppler ultrasound in dialysis access. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfh244
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.