Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 177

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Serum cystatin C as an endogenous marker of renal function in patients with mild to moderate impairment of kidney function

Open access
Hojs, Radovan, Bevc, Sebastjan, Ekart, Robert, Gorenjak, Maksimiljan, Puklavec, Ludvik · 2006 · Nephrology Dialysis Transplantation

Abstract

BACKGROUND: Estimation of the glomerular filtration rate (GFR) is essential for the evaluation of patients with chronic kidney disease (CKD). Recently, serum cystatin C was proposed as a new endogenous marker of GFR and in our study its diagnostic accuracy was compared with that of other markers of GFR. METHODS: In this study, 164 patients with CKD stages 2-3 (GFR 30-89 ml/min/1.73 m2), who had performed 51Cr-labelled ethylenediaminetetra-acetic acid clearance, were enrolled. In each patient, serum creatinine and serum cystatin C were determined. Creatinine clearance was calculated using the Cockcroft-Gault (C&G) and the modification of diet in renal disease (MDRD) formulas. RESULTS: The mean 51CrEDTA clearance was 57 ml/min/1.73 m2, the mean serum creatinine 149 micromol/l and the mean serum cystatin C 1.74 mg/l. We found significant correlation between 51CrEDTA clearance and serum creatinine (R = -0.666), serum cystatin C (R = -0.792), reciprocal of serum creatinine (R = 0.628), reciprocal of serum cystatin C (R = 0.753) and calculated creatinine clearance from the formulas C&G (R = 0.515) and MDRD formulas (R = 0.716). The receiver operating characteristic (ROC) curve analysis (cut-off for GFR 60 ml/min/1.73 m2) showed that serum cystatin C had a significantly higher diagnostic accuracy than serum creatinine (P = 0.04) and calculated creatinine clearance from the C&G formula (P < 0.0001), though only in female patients. No difference in diagnostic accuracy was found between serum cystatin C and creatinine clearance calculated from the MDRD formula. CONCLUSIONS: Our results indicate that serum cystatin C is a reliable marker of GFR in patients with mildly to moderately impaired kidney function and has a higher diagnostic accuracy than serum creatinine and calculated creatinine clearance from the C&G formula in female patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfl073

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Hojs, R., Bevc, S., Ekart, R., Gorenjak, M., & Puklavec, L.
Venue
Nephrology Dialysis Transplantation
Published
2006-03-08
Volume
21
Issue
7
Pages
1855-1862
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2129899223
Cited by
177
References
1
FWCI
7.77
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.