Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 184

The DOI matches its Crossref record.

A systematic review of the clinical effects of reducing dialysate fluid temperature

Open access
Selby, Nicholas M., McIntyre, Christopher W. · 2006 · Nephrology Dialysis Transplantation

Abstract

BACKGROUND: Intradialytic hypotension (IDH) is a frequent complication of haemodialysis. Reducing the temperature of the dialysis fluid is a simple therapeutic strategy but is relatively underused. This may be due to concerns regarding its effects on symptoms and dialysis adequacy. We performed a systematic review of the literature to examine the effects of cool dialysis on intradialytic blood pressure, and to assess its safety in terms of thermal symptoms and small solute clearance. METHODS: We searched the Cochrane Central Register of Controlled Trials, Medline, Embase, Cumulative Index to Nursing and Allied Health Literature, databases of ongoing trials, the contents of four major renal journals as well as hand-searching reference lists. We included all prospective randomized studies that compared any technique of reducing dialysate temperature with standard bicarbonate dialysis. These techniques included an empirical, fixed reduction of dialysate temperature or use of a biofeedback temperature-control device (BTM) to deliver isothermic dialysis or programmed patient cooling. RESULTS: A total of 22 studies comprising 408 patients were included (16 studies examined a fixed empirical temperature reduction and six examined BTM). All studies were of crossover design and relatively short duration. IDH occurred 7.1 (95% CI, 5.3-8.9) times less frequently with cool dialysis (both fixed reduction and BTM). Post-dialysis mean arterial pressure was higher with cool-temperature dialysis by 11.3 mmHg (95% CI, 7.7-15.0). No studies reported that cool dialysis led to a reduction in dialysis adequacy as assessed by urea clearance. The frequency and severity of thermal-related symptoms were generally reported inadequately. CONCLUSIONS: Reducing the temperature of the dialysate is an effective intervention to reduce the frequency of IDH and does not adversely affect dialysis adequacy. This applies to the fixed reduction of dialysate temperature and BTM. It remains unclear as to what extent cool-temperature dialysis causes intolerable cold symptoms during dialysis. There are no trials comparing fixed empirical temperature reduction with BTM, and no trials examining the long-term effects of cool dialysis on patient outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfl126

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 184

Metadata

Authors
Selby, N. M., & McIntyre, C. W.
Venue
Nephrology Dialysis Transplantation
Published
2006-04-06
Volume
21
Issue
7
Pages
1883-1898
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2161732800
Cited by
184
References
0
FWCI
1.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A systematic review of the clinical effects of reducing dialysate fluid temperature. https://app.cochat.ai/papers/10.1093/ndt/gfl126
The paper
Selby, N. M., & McIntyre, C. W. (2006). A systematic review of the clinical effects of reducing dialysate fluid temperature. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfl126

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.