Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 566

The DOI matches its Crossref record.

Vascular access use and outcomes: an international perspective from the dialysis outcomes and practice patterns study

Open access
Ethier, J., Mendelssohn, D. C., Elder, S. J., Hasegawa, T., Akizawa, T., Akiba, T., Canaud, B. J., Pisoni, R. L.·2008·Nephrology Dialysis Transplantation

Abstract

BACKGROUND: A well-functioning vascular access (VA) is essential to efficient dialysis therapy. Guidelines have been implemented improving care, yet access use varies widely across countries and VA complications remain a problem. This study took advantage of the unique opportunity to utilize data from the Dialysis Outcomes and Practice Patterns Study (DOPPS) to examine international trends in VA use and trends in patient characteristics and practices associated with VA use from 1996 to 2007. DOPPS is a prospective, observational study of haemodialysis (HD) practices and patient outcomes at >300 HD units from 12 countries and has collected data thus far from >35,000 randomly selected patients. METHODS: VA data were collected for each patient at study entry (1996-2007). Practice pattern data from the facility medical director, nurse manager and VA surgeon were also analysed. RESULTS: Since 2005, a native arteriovenous fistula (AVF) was used by 67-91% of prevalent patients in Japan, Italy, Germany, France, Spain, the UK, Australia and New Zealand, and 50-59% in Belgium, Sweden and Canada. From 1996 to 2007, AVF use rose from 24% to 47% in the USA but declined in Italy, Germany and Spain. Moreover, graft use fell by 50% in the USA from 58% use in 1996 to 28% by 2007. Across three phases of data collection, patients consistently were less likely to use an AVF versus other VA types if female, of older age, having greater body mass index, diabetes, peripheral vascular disease or recurrent cellulitis/gangrene. In addition, countries with a greater prevalence of diabetes in HD patients had a significantly lower percentage of patients using an AVF. Despite poorer outcomes for central vein catheters, catheter use rose 1.5- to 3-fold among prevalent patients in many countries from 1996 to 2007, even among non-diabetic patients 18-70 years old. Furthermore, 58-73% of patients new to end-stage renal disease (ESRD) used a catheter for the initiation of HD in five countries despite 60-79% of patients having been seen by a nephrologist >4 months prior to ESRD. Patients were significantly (P < 0.05) less likely to start dialysis with a permanent VA if treated in a faciity that (1) had a longer time from referral to access surgery evaluation or from evaluation to access creation and (2) had longer time from access creation until first AVF cannulation. The median time from referral until access creation varied from 5-6 days in Italy, Japan and Germany to 40-43 days in the UK and Canada. Compared to patients using an AVF, patients with a catheter displayed significantly lower mean Kt/V levels. CONCLUSIONS: Most countries meet the contemporary National Kidney Foundation's Kidney Disease Outcomes Quality Initiative goal for AVF use; however, there is still a wide variation in VA preference. Delays between the creation and cannulation must be improved to enhance the chances of a future permanent VA. Native arteriovenous fistula is the VA of choice ensuring dialysis adequacy and better patient outcomes. Graft is, however, a better alternative than catheter for patients where the creation of an attempted AVF failed or could not be created for different reasons.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/gfn261

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 566

Metadata

Authors
Ethier, J., Mendelssohn, D. C., Elder, S. J., Hasegawa, T., Akizawa, T., Akiba, T., Canaud, B. J., & Pisoni, R. L.
Venue
Nephrology Dialysis Transplantation
Published
2008-06-16
Volume
23
Issue
10
Pages
3219-3226
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2148042420
Cited by
566
References
0
FWCI
51.28
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vascular access use and outcomes: an international perspective from the dialysis outcomes and practice patterns study. https://app.cochat.ai/papers/10.1093/ndt/gfn261
The paper
Ethier, J., Mendelssohn, D. C., Elder, S. J., Hasegawa, T., Akizawa, T., Akiba, T., Canaud, B. J., & Pisoni, R. L. (2008). Vascular access use and outcomes: an international perspective from the dialysis outcomes and practice patterns study. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfn261

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.