CoChat

Safety and Efficacy of a Novel, Self-Adhering Dural Substitute in a Canine Supratentorial Durotomy Model

Open access
Lewis, Kevin M, Sweet, Jenifer, Wilson, Scott T, Rousselle, Serge, Gulle, Heinz, Baumgartner, Bernhard · 2018 · Neurosurgery
Cited by 25

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Cerebrospinal fluid (CSF) leaks increase postoperative risk for complication, likelihood of reoperation, and costs. OBJECTIVE: To investigate a novel, self-adhering polyethylene glycol-coated collagen pad (PCC) as a dural substitute relative to Duragen XS (DGX; Integra LifeSciences Corporation, Plainsboro, New Jersey) and as a dural sealant relative to Tachosil (Takeda Austria GmbH, Linz, Austria), a fibrinogen and thrombin-coated collagen pad (FTC). METHODS: A canine supratentorial durotomy surgical model was used to investigate the safety and efficacy of PCC. For safety, 4 animals were bilaterally treated with DGX or PCC and recovered for 1, 8, or 16 wk; total 24 animals. Each animal underwent physical and neurological examinations weekly and 16-wk animals underwent a magnetic resonance imaging (MRI) examination at each time point. For efficacy, 9 animals were unilaterally treated with FTC or PCC and underwent a burst pressure test intraoperatively or 14 d postoperatively; total 36 animals. RESULTS: In the safety study, no abnormal clinical signs or changes were noted on physical and neurological examinations, or in clinical pathology, CSF analysis or histopathology of DGX or PCC-treated animals. No consistent signs of cerebral compression, CSF leak, hemorrhage, or hydrocephalus were noted on MRI. In the efficacy study, no significant difference was found between FTC and PCC at each time point or overall (13.9 vs 12.3 mm Hg, n = 18 per group, P = .46). CONCLUSION: PCC is safe for use as a dural substitute and effective as a dural sealant. The novel, self-adhering combination of a polyethylene glycol-based sealant and a collagen pad may offer unique benefits to the advancement of duraplasty.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/neuros/nyx216

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Metadata

Authors
Lewis, K. M., Sweet, J., Wilson, S. T., Rousselle, S., Gulle, H., & Baumgartner, B.
Venue
Neurosurgery
Published
2017-06-01
Volume
82
Issue
3
Pages
397-406
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2620825838
Cited by
25
References
1
FWCI
1.63
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Safety and Efficacy of a Novel, Self-Adhering Dural Substitute in a Canine Supratentorial Durotomy Model. https://app.cochat.ai/papers/10.1093/neuros/nyx216
The paper
Lewis, K. M., Sweet, J., Wilson, S. T., Rousselle, S., Gulle, H., & Baumgartner, B. (2018). Safety and Efficacy of a Novel, Self-Adhering Dural Substitute in a Canine Supratentorial Durotomy Model. Neurosurgery. https://doi.org/10.1093/neuros/nyx216

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.