CoChat

Near Real-Time Intraoperative Brain Tumor Diagnosis Using Stimulated Raman Histology and Deep Neural Networks

Hollon, Todd C, Pandian, Balaji, Khalsa, Siri Sahib Singh, D'Amico, Randy, Sisti, Michael B, Bruce, Jeffrey N, Muraszko, Karin M, Thompson, Gregory B, Freudiger, Christian, Hervey-Jumper, Shawn L, McKhann, Guy M, Camelo-Piragua, Sandra, Canoll, Peter D, Lee, Honglak, Orringer, Daniel A · 2019 · Neurosurgery
Cited by 79

The DOI matches its Crossref record.

Abstract

INTRODUCTION: Intraoperative diagnosis is essential for providing safe and effective care during cancer surgery. The existing workflow for intraoperative diagnosis based on H&E staining of processed tissue is time-, resource-, and labor-intensive. Moreover, interpretation of intraoperative histologic images is dependent on a pathology workforce that is contracting and unevenly distributed across the centers where cancer surgery is performed worldwide. METHODS: We developed an automated workflow, independent of traditional H&E histology, that combines stimulated Raman histology (SRH), a rapid label-free optical imaging method, and deep convolutional neural networks (CNN) to predict diagnosis at the bedside in near real time. Specifically, our CNN, trained on over 2.5 million SRH images, predicts brain tumor diagnosis in the operating room in under 150 s, which is an order of magnitude faster than conventional techniques (eg, 20-30 min). RESULTS: To validate our workflow in the clinical setting, we designed a multicenter, prospective, noninferiority clinical trial (N = 204) that compares SRH plus CNN vs traditional H&E histology. Primary endpoint was overall diagnostic accuracy. We show that CNN-based diagnosis of SRH images was noninferior to pathologist-based interpretation of conventional histologic images (overall accuracy, 94.6% vs 95.5%). Additionally, our CNN learned a hierarchy of interpretable histologic feature representations to classify the major histopathologic classes of brain tumors. We then developed and implemented a semantic segmentation method that can identify tumor infiltrated and diagnostic regions within SRH images. Mean intersection over union values was 61 ± 28.6 for ground truth diagnostic class and 86.0 ± 28.6 for tumor-infiltrated regions. CONCLUSION: We have demonstrated how combining bedside optical histology with deep learning can result in near real-time intraoperative brain tumor diagnosis. Our workflow provides a means of delivering expert-level intraoperative diagnosis where neuropathology resources are scarce and improve diagnostic accuracy in resource-rich centers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/neuros/nyz310_634

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 79

Metadata

Authors
Hollon, T. C., Pandian, B., Khalsa, S. S. S., D'Amico, R., Sisti, M. B., Bruce, J. N., Muraszko, K. M., Thompson, G. B., Freudiger, C., Hervey-Jumper, S. L., McKhann, G. M., Camelo-Piragua, S., Canoll, P. D., Lee, H., & Orringer, D. A.
Venue
Neurosurgery
Published
2019-09
Volume
66
Issue
Supplement 1
Pages
310-634
ISSN
0148-396X (ISSN-L)
OpenAlex
W2969250894
Cited by
79
References
0
FWCI
4.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Near Real-Time Intraoperative Brain Tumor Diagnosis Using Stimulated Raman Histology and Deep Neural Networks. https://app.cochat.ai/papers/10.1093/neuros/nyz310_634
The paper
Hollon, T. C., Pandian, B., Khalsa, S. S. S., D'Amico, R., Sisti, M. B., Bruce, J. N., Muraszko, K. M., Thompson, G. B., Freudiger, C., Hervey-Jumper, S. L., McKhann, G. M., Camelo-Piragua, S., Canoll, P. D., Lee, H., & Orringer, D. A. (2019). Near Real-Time Intraoperative Brain Tumor Diagnosis Using Stimulated Raman Histology and Deep Neural Networks. Neurosurgery. https://doi.org/10.1093/neuros/nyz310_634

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.