CoChat
Cited by 204

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Biocompatible zinc battery with programmable electro-cross-linked electrolyte

Open access
Xie, Xuesong, Li, Jingjing, Xing, Zhengyue, Lu, Bingan, Liang, Shuquan, Zhou, Jiang · 2023 · National Science Review

Abstract

Aqueous zinc batteries (ZBs) attract increasing attention for potential applications in modern wearable and implantable devices due to their safety and stability. However, challenges associated with biosafety designs and the intrinsic electrochemistry of ZBs emerge when moving to practice, especially for biomedical devices. Here, we propose a green and programmable electro-cross-linking strategy to in situ prepare a multi-layer hierarchical Zn–alginate polymer electrolyte (Zn–Alg) via the superionic binds between the carboxylate groups and Zn2+. Consequently, the Zn–Alg electrolyte provides high reversibility of 99.65% Coulombic efficiency (CE), >500 h of long-time stability and high biocompatibility (no damage to gastric and duodenal mucosa) in the body. A wire-shaped Zn/Zn–Alg/α-MnO2 full battery affords 95% capacity retention after 100 cycles at 1 A g−1 and good flexibility. The new strategy has three prominent advantages over the conventional methods: (i) the cross-linking process for the synthesis of electrolytes avoids the introduction of any chemical reagents or initiators; (ii) a highly reversible Zn battery is easily provided from a micrometer to large scales through automatic programmable functions; and (iii) high biocompatibility is capable of implanted and bio-integrated devices to ensure body safety.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/nsr/nwac281

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • “Water-in-salt” electrolyte enables high-voltage aqueous lithium-ion chemistries

    Suo, L., Borodin, O., Gao, T., Olguin, M., Ho, J., Fan, X., Luo, C., Wang, C., & Xu, K. (2015) · Science · doi:10.1126/science.aab1595 · Cited by 3,821 · cited 1×

    “Increasing safety concerns over the routine use of flammable and unstable organic electrolytes are challenging conventional alkali metal-ion batteries, posing a formidable barrier to the application of modernly portable and implantable electronics [1,2].”
    Background
  • Flexible and Stretchable Electronics for Biointegrated Devices

    Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749 · cited 1×

    “As a crucial part of the battery, the flexible hydrogel electrolyte is suitable for wearable devices to integrate with biological tissues by attaching to soft and curvilinear shapes [12], which have been developed to monitor electrophysiological signals [13], deliver therapeutic drugs [14] and be applied as a novel no…”
    Background

Cited by

See all 204

Metadata

Authors
Xie, X., Li, J., Xing, Z., Lu, B., Liang, S., & Zhou, J.
Venue
National Science Review
Published
2022-12-14
Volume
10
Issue
3
Pages
nwac281-nwac281
ISSN
  • 2053-714X (ISSN-L)
  • 2095-5138
OpenAlex
W4311458834
Cited by
204
References
2
FWCI
12.25
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.