Microrheology
The DOI matches its Crossref record; 224 of the 224 references it cites were found in a registry or an index.
Abstract
We present a comprehensive overview of microrheology, emphasizing the underlying theory, practical aspects of its implementation, and current applications to rheological studies in academic and industrial laboratories. Key methods and techniques are examined, including important considerations to be made with respect to the materials most amenable to microrheological characterization and pitfalls to avoid in measurements and analysis. The fundamental principles of all microrheology experiments are presented, including the nature of colloidal probes and their movement in fluids, soft solids, and viscoelastic materials. Microrheology is divided into two general areas, depending on whether the probe is driven into motion by thermal forces (passive), or by an external force (active). We present the theory and practice of passive microrheology, including an in-depth examination of the Generalized Stokes-Einstein Relation (GSER). We carefully treat the assumptions that must be made for these techniques to work, and what happens when the underlying assumptions are violated. Experimental methods covered in detail include particle tracking microrheology, tracer particle microrheology using dynamic light scattering and diffusing wave spectroscopy, and laser tracking microrheology. Second, we discuss the theory and practice of active microrheology, focusing specifically on the potential and limitations of extending microrheology to measurements of non-linear rheological properties, like yielding and shear-thinning. Practical aspects of magnetic and optical tweezer measurements are preseted. Finally, we highlight important applications of microrheology, including measurements of gelation, degradation, high-throughput rheology, protein solution viscosities, and polymer dynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–224 of 224
Three-Dimensional Cellular Deformation Analysis with a Two-Photon Magnetic Manipulator Workstation
Huang, H., Dong, C., Kwon, H.-S., Sutin, J. D. B., Kamm, R. D., & So, P. T. C. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75567-7 · Cited by 78
Evident atoms: visuality in Jean Perrin’s Brownian motion research
Bigg, C. (2008) · Studies in History and Philosophy of Science Part A · doi:10.1016/j.shpsa.2008.06.003 · Cited by 78
Optical trapping for undergraduates
Appleyard, D. C., Vandermeulen, K. Y., Lee, H., & Lang, M. J. (2006) · American Journal of Physics · doi:10.1119/1.2366734 · Cited by 77
Nonlinear microrheology of an aging, yield stress fluid using magnetic tweezers
Rich, J. P., Lammerding, J., McKinley, G. H., & Doyle, P. S. (2011) · Soft Matter · doi:10.1039/c1sm05843f · Cited by 72
Diffusing Wave Spectroscopy of aggregating and gelling systems
Alexander, M., & Dalgleish, D. G. (2007) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2007.07.008 · Cited by 72
Small amplitude active oscillatory microrheology of a colloidal suspension
Sriram, I., Furst, E. M., DePuit, R. J., & Squires, T. M. (2009) · Journal of Rheology · doi:10.1122/1.3058438 · Cited by 72
Self-citationThe flexure-based microgap rheometer (FMR)
Clasen, C., Gearing, B. P., & McKinley, G. H. (2006) · Journal of Rheology · doi:10.1122/1.2357190 · Cited by 70
Noncontact microrheology at acoustic frequencies using frequency-modulated atomic force microscopy
Gavara, N., & Chadwick, R. S. (2010) · Nature Methods · doi:10.1038/nmeth.1474 · Cited by 68
High-resolution detection of Brownian motion for quantitative optical tweezers experiments
Grimm, M., Franosch, T., & Jeney, S. (2012) · Physical Review E · doi:10.1103/physreve.86.021912 · Cited by 68
Hydrogel microrheology near the liquid-solid transition
Larsen, T. H., Schultz, K. M., & Furst, E. M. (2008) · Korea-Australia Rheology Journal · Cited by 67
Self-citationProbing linear and nonlinear microrheology of viscoelastic fluids
Gomez-Solano, J. R., & Bechinger, C. (2014) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/108/54008 · Cited by 61
Gel time prediction of multifunctional acrylates using a kinetics model
Boddapati, A., Rahane, S. B., Slopek, R. P., Breedveld, V., Henderson, C. L., & Grover, M. A. (2010) · Polymer · doi:10.1016/j.polymer.2010.12.024 · Cited by 58
Measuring the Modulus and Reverse Percolation Transition of a Degrading Hydrogel
Schultz, K. M., Baldwin, A. D., Kiick, K. L., & Furst, E. M. (2012) · ACS Macro Letters · doi:10.1021/mz300106y · Cited by 55
Self-citationLiquid diffusion applied to analysis
Graham, T. J. (1861) · Journal of the Franklin Institute · doi:10.1016/0016-0032(61)90352-0 · Cited by 53
Sato, J., & Breedveld, V. (2005) · Journal of Rheology · doi:10.1122/1.2135329 · Cited by 53
Johansson, C., Hanson, M., Pedersen, M. S., & Mørup, S. (1997) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(97)00168-6 · Cited by 44
Flocculation of Latices by Low Molecular Weight Polymers
Evans, R., & Napper, D. H. (1973) · Nature · doi:10.1038/246034a0 · Cited by 39
High throughput system for magnetic manipulation of cells, polymers, and biomaterials
Spero, R. C., Vicci, L., Cribb, J., Bober, D. B., Swaminathan, V., O’Brien, E. T., Rogers, S. L., & Superfine, R. (2008) · Review of Scientific Instruments · doi:10.1063/1.2976156 · Cited by 37
High-force NdFeB-based magnetic tweezers device optimized for microrheology experiments
Lin, J., & Valentine, M. T. (2012) · Review of Scientific Instruments · doi:10.1063/1.4719916 · Cited by 36
Electrospinning covalently cross-linking biocompatible hydrogelators
Schultz, K. M., Campo-Deaño, L., Baldwin, A. D., Kiick, K. L., Clasen, C., & Furst, E. M. (2012) · Polymer · doi:10.1016/j.polymer.2012.09.060 · Cited by 32
Self-citationPrinciples and Applications of Diffusing-Wave Spectroscopy
Weitz, D. A., Zhu, J., Durian, D. J., & Pine, D. J. (1992) · Springer eBooks · doi:10.1007/978-94-011-2540-6_36 · Cited by 31
Simple method for measuring refractive index of supercritical fluids
Kirby, C. F., & McHugh, M. A. (1997) · Review of Scientific Instruments · doi:10.1063/1.1148260 · Cited by 30
Zacchia, N. A., & Valentine, M. T. (2015) · Review of Scientific Instruments · doi:10.1063/1.4921553 · Cited by 25
Frequency modulated microrheology
Shindel, M. M., & Furst, E. M. (2015) · Lab on a Chip · doi:10.1039/c5lc00351b · Cited by 21
Self-citation
Cited by
Translational Applications of Hydrogels
Correa, S., Grosskopf, A. K., Lopez Hernandez, H., Chan, D., Yu, A. C., Stapleton, L. M., & Appel, E. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01177 · Cited by 1,143
Molecular Characterization of Polymer Networks
Danielsen, S. P. O., Beech, H. K., Wang, S., El-Zaatari, B. M., Wang, X., Sapir, L., Ouchi, T., Wang, Z., Johnson, P. N., Hu, Y., et al. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01304 · Cited by 336
Metadata
- Authors
- Furst, E. M., & Squires, T. M.
- Publisher
- Oxford University PressOxford
- Published
- 2017-10-05
- OpenAlex
- W4243234705
- Cited by
- 197
- References
- 224
- FWCI
- 14.99
- Type
- book
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.