NOSOCOMIAL BLOODSTREAM INFECTIONS IN A NEWBORN INTENSIVE CARE UNIT
The DOI matches its Crossref record.
Abstract
Routine surveillance of 1252 newborns admitted over a four-year period to a newborn intensive care unit (ICU) identified 49 (4%) with nosocomial bloodstream infections. Forty-nine control subjects without such infections were selected, matching for birth weight, gestational age, and at least three diagnoses per patient. Overall, 27% of cases and 6% of controls died (p = 0.01) and significant differences persisted when cases with multiple bloodstream infections were removed from analysis. Although small numbers of case-control pairs remained for analysis, significant differences disappeared when cases with multiple bloodstream infections plus case-control pairs discordant for presence/absence of nosocomial infections at other sites were eliminated from comparison. On the average, all cases and controls were hospitalized for 70 +/- 14 days and 50 +/- 8 days, respectively, but when cases with multiple bloodstream infections or the multiple bloodstream infections-discordant pair group were removed from analysis, the significant difference in hospitalization disappeared. A strong association between nosocomial infections at sites other than the bloodstream and bloodstream infections was demonstrated and may suggest a means of reducing the incidence of bloodstream infections in a high risk population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
National nosocomial infections surveillance system (NNIS): Description of surveillance methods
Emori, T. G., Culver, D. H., Horan, T. C., Jarvis, W. R., White, J. W., Olson, D. R., Banerjee, S., Edwards, J. R., Martone, W. J., Gaynes, R. P., et al. (1991) · American Journal of Infection Control · doi:10.1016/0196-6553(91)90157-8 · Cited by 832
Hospital-Acquired Candidemia: The Attributable Mortality and Excess Length of Stay
Wey, S. B. (1988) · Archives of Internal Medicine · doi:10.1001/archinte.1988.00380120094019 · Cited by 831
Jarvis, W. R. (1996) · Infection Control & Hospital Epidemiology · doi:10.1086/647371 · Cited by 487
The Role of Understaffing in Central Venous Catheter-Associated Bloodstream Infection
Fridkin, S. K., Pear, S. M., Williamson, T. H., Galgiani, J. N., & Jarvis, W. R. (1996) · Infection Control and Hospital Epidemiology · doi:10.1017/s0195941700006445 · Cited by 447
Nosocomial Infection and Fatality in Medical and Surgical Intensive Care Unit Patients
Craven, D. E. (1988) · Archives of Internal Medicine · doi:10.1001/archinte.148.5.1161 · Cited by 359
Metadata
- Authors
- TOWNSEND, T. R., & WENZEL, R. P.
- Venue
- American Journal of Epidemiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1981-07
- Volume
- 114
- Issue
- 1
- Pages
- 73-80
- ISSN
- 0002-9262 (ISSN-L)
- 1476-6256
- OpenAlex
- W2263932836
- Cited by
- 92
- References
- 0
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NOSOCOMIAL BLOODSTREAM INFECTIONS IN A NEWBORN INTENSIVE CARE UNIT. https://app.cochat.ai/papers/10.1093/oxfordjournals.aje.a113176
- The paper
- TOWNSEND, T. R., & WENZEL, R. P. (1981). NOSOCOMIAL BLOODSTREAM INFECTIONS IN A NEWBORN INTENSIVE CARE UNIT. American Journal of Epidemiology. https://doi.org/10.1093/oxfordjournals.aje.a113176
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.