The DOI matches its Crossref record.
AN EPIDEMIOLOGIC STUDY OF THE RISKS ASSOCIATED WITH PERIPHERAL INTRAVENOUS CATHETERS
Abstract
Tager, I. B. (Channing Laboratory, Boston, MA 02115), M. B. Ginsberg, S. E. Ellis, N. E. Walsh, I. Dupont, E. Simchen, G. A. Falch and the Rhode Island Nosocomlal Infection Consortium. An epidemiologic study of the risks associated with peripheral Intravenous catheters. Am J Epidemiol 1983;118:839–51. As part of a standardized, multi-hospital prospective surveillance system for nosocomlal infections in Rhode island, an analysis was undertaken in March 1980-February 1982 to determine the interplay of factors that contribute to the risk of phlebitis in peripheral, non-steel, non-butterfly intravenous catheters. The authors studied 3094 patients with 5161 total episodes of peripheral intravenous catheters from day of admission until day of discharge. The overall rate of phlebitis was 2.3% (118 episodes), and the rate of intravenous catheter-associated bacteremia was 0.08% (1 definite episode, 3 possible episodes). Factors significantly associated with the occurrence of phlebitis were: underlying risk for any nosocomlal infection, duration of the catheter episode, chronological order of the episode and an interaction between the latter two variables. Analysis of day-specific risk of phlebitis indicated that, for patients with low risk diagnoses, initial peripheral intravenous catheters might be left In place with relative safety for up to 96 hours. Over this time period, the day-specific risk for such patients ranged between 0.8% and 1.4%, exclusive of the first day. In all other circumstances, the current recommendation of 48–72 hours seems appropriate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control and Hospital Epidemiology · doi:10.1086/502007 · Cited by 847
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir138 · Cited by 560
Guideline for Prevention of Intravascular-Device-Related Infections
Pearson, M. L., & The Hospital Infection Control Practices Advisory Committee (1996) · Infection Control and Hospital Epidemiology · doi:10.2307/30141155 · Cited by 531
Metadata
- Authors
- THE RHODE ISLAND NOSOCOMIAL INFECTION CONSORTIUM, TAGER, I. B., GINSBERG, M. B., ELLIS, S. E., WALSH, N. E., DUPONT, I., SIMCHEN, E., & FAICH, G. A.
- Venue
- American Journal of Epidemiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1983-12-01
- Volume
- 118
- Issue
- 6
- Pages
- 839-851
- ISSN
- 0002-9262 (ISSN-L)
- 1476-6256
- OpenAlex
- W2257933825
- Cited by
- 189
- References
- 0
- FWCI
- 4.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AN EPIDEMIOLOGIC STUDY OF THE RISKS ASSOCIATED WITH PERIPHERAL INTRAVENOUS CATHETERS. https://app.cochat.ai/papers/10.1093/oxfordjournals.aje.a113702
- The paper
- THE RHODE ISLAND NOSOCOMIAL INFECTION CONSORTIUM, TAGER, I. B., GINSBERG, M. B., ELLIS, S. E., WALSH, N. E., DUPONT, I., SIMCHEN, E., & FAICH, G. A. (1983). AN EPIDEMIOLOGIC STUDY OF THE RISKS ASSOCIATED WITH PERIPHERAL INTRAVENOUS CATHETERS. American Journal of Epidemiology. https://doi.org/10.1093/oxfordjournals.aje.a113702
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.