Calibration of Dietary Intake Measurements in Prospective Cohort Studies
The DOI matches its Crossref record.
Abstract
To evaluate the accuracy of dietary intake measurements in prospective cohort studies on diet, it is generally proposed that substudies be conducted to 1) correct relative risk estimates for biases due to measurement error, and 2) account for statistical power losses when estimating the sample size requirements of the cohort. Usually the substudy takes the form of a "validity" study, based on a small group of volunteers and using repeated daily food consumption records as reference measurements. In this methodological review, the authors conclude that when relative risks are estimated for scaled, absolute intake differences rather than for quantile categories, a "calibration" study based on only a single day's food intake record (but generally on a larger number of subjects) can provide sufficient reference information to meet objectives 1 and 2. A major advantage of calibration studies based on this single-day-per-subject design is that they can be conducted on a representative sample of cohort participants more easily than validity studies in which reference measurements are repeated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Riboli, E., Hunt, K., Slimani, N., Ferrari, P., Norat, T., Fahey, M., Charrondière, U., Hémon, B., Casagrande, C., Vignat, J., et al. (2002) · Public Health Nutrition · doi:10.1079/phn2002394 · Cited by 1,866
“The calibration study, its rationale and its standardisation are described in detail elsewhere 25–31 .”
MethodSelf-citationBingham, S. A., Day, N. E., Luben, R., Ferrari, P., Slimani, N., Norat, T., Clavel-Chapelon, F., Kesse, E., Nieters, A., Boeing, H., et al. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13174-1 · Cited by 1,111
Self-citationA Multiethnic Cohort in Hawaii and Los Angeles: Baseline Characteristics
Kolonel, L. N., Henderson, B. E., Hankin, J. H., Nomura, A. M. Y., Wilkens, L. R., Pike, M. C., Stram, D. O., Monroe, K. R., Earle, M. E., & Nagamine, F. S. (2000) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a010213 · Cited by 1,021
Riboli, E. (1997) · International Journal of Epidemiology · doi:10.1093/ije/26.suppl_1.s6 · Cited by 945
Self-citationFernández-Ballart, J. D., Piñol, J. L., Zazpe, I., Corella, D., Carrasco, P., Toledo, E., Perez-Bauer, M., Martínez-González, M. Á., Salas-Salvadó, J., & Martín-Moreno, J. M. (2010) · British Journal of Nutrition · doi:10.1017/s0007114509993837 · Cited by 898
Metadata
- Authors
- Kaaks, R., Riboli, E., & van Staveren, W.
- Venue
- American Journal of Epidemiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-09-01
- Volume
- 142
- Issue
- 5
- Pages
- 548-556
- ISSN
- 0002-9262 (ISSN-L)
- 1476-6256
- OpenAlex
- W2160838810
- Cited by
- 125
- References
- 0
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration of Dietary Intake Measurements in Prospective Cohort Studies. https://app.cochat.ai/papers/10.1093/oxfordjournals.aje.a117673
- The paper
- Kaaks, R., Riboli, E., & van Staveren, W. (1995). Calibration of Dietary Intake Measurements in Prospective Cohort Studies. American Journal of Epidemiology. https://doi.org/10.1093/oxfordjournals.aje.a117673
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.