CoChat
Cited by 168

The DOI matches its Crossref record.

Physical responses to different modes of interval exercise in patients with chronic heart failure--application to exercise training

Meyer, K., Samek, L., Schwaibold, M., Westbrook, S., Hajric, R., Lehmann, M., Essfeld, D., Roskamm, H. · 1996 · European Heart Journal

Abstract

METHOD: In exercise training with chronic heart failure patients, working muscles should be stressed with high intensity stimuli without causing cardiac overstraining. This is possible using interval method exercise. In this study, three interval exercise modes with different ratios of work/ recovery phases (30/60 s, 15/60 s and 10/60 s) and different work rates were compared during cycle ergometer exercise in heart failure patients. Work rate for the three interval modes was 50% (30/60 s), 70% (15/60 s) and 80% (10/60 s) of the maximum achieved during a steep ramp test (increments of 25 w/10 s) corresponding to 71, 98 and 111 watts on average. Metabolic and cardiac responses to the three interval exercises were then examined including catecholamine levels and perceived exertion. Parameters measured during interval exercise were compared with an intensity level of 75% peak VO2, determined during an ordinary ramp exercise test (increments of 12.5 W.min-1). RESULTS: (mean +/- SEM) (1) In all three interval modes, VO2, ventilation and lactate did not increase significantly during the course of exercise. Mean values during the last work phase were between 754 +/- 30 and 803 +/- 46 ml.min-1 for VO2, between 26 +/- 3 and 28 +/- 1 l.min-1 for ventilation and between 1.24 +/- 0.14 and 1.29 +/- 0.10 mmol.l-1 for lactate. (2) In mode 10/60 s, heart rate and systolic blood pressure increased significantly (82 +/- 4 --> 85 +/- 4 beats.min-1; 124 +/- 5 --> 134 +/- 5 mmHg; P < 0.05 each), while in mode 15/60 s catecholamines increased significantly (norepinephrine 0.804 +/- 0.089 --> 1.135 +/- 0.094 nmol.l-1; P < 0.008; epinephrine 0.136 +/- 0.012 --> 0.193 +/- 0.019 nmol.l-1; P < 0.005). (3) In all three modes, rating of leg fatigue and dyspnoea increased significantly during exercise but remained within the range of values considered 'very light to fairly light' on the Borg scale. (4) Compared to an intensity level of 75% peak VO2, work rate during interval work phases was between 143 and 221%, while cardiac stress (rate-pressure product) was significantly lower (83-88%). CONCLUSION: All three interval modes resulted in physical response in an acceptable range of values, and thus can be recommended.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/oxfordjournals.eurheartj.a015000

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 168

Metadata

Authors
Meyer, K., Samek, L., Schwaibold, M., Westbrook, S., Hajric, R., Lehmann, M., Essfeld, D., & Roskamm, H.
Venue
European Heart Journal
Published
1996-07-01
Volume
17
Issue
7
Pages
1040-1047
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2008513720
Cited by
168
References
0
FWCI
21.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Physical responses to different modes of interval exercise in patients with chronic heart failure--application to exercise training. https://app.cochat.ai/papers/10.1093/oxfordjournals.eurheartj.a015000
The paper
Meyer, K., Samek, L., Schwaibold, M., Westbrook, S., Hajric, R., Lehmann, M., Essfeld, D., & Roskamm, H. (1996). Physical responses to different modes of interval exercise in patients with chronic heart failure--application to exercise training. European Heart Journal. https://doi.org/10.1093/oxfordjournals.eurheartj.a015000

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.