Conversion of atrial fibrillation to sinus rhythm and rate control by digoxin in comparison to placebo
The DOI matches its Crossref record.
Abstract
AIMS: A randomized, double-blind study with a high dose of digoxin administered intravenously for conversion of atrial fibrillation (not due to haemodynamic alternations) to sinus rhythm, and for rate control in converters and non-converters was set up. Outcome measures were conversion within 12 h; time to conversion; early rate control; and stable slowing within 12 h. METHODS: We studied 40 patients with recent onset (< 1 week) atrial fibrillation; controls received saline intravenously, the other patients digoxin 1.25 mg. RESULTS: One patient converted before digoxin administration. Conversion occurred in 9/19 patients on digoxin and in 8/20 on placebo (ns). The mean time to conversion tended to be shorter only for digoxin. Two late conversions on placebo were observed within 24 h. Heart rate during atrial fibrillation decreased after 30 min for converters and non-converters (P < 0.05). For all patients on digoxin, heart rate after 30 min was lower compared to baseline (P < 0.002) and to placebo (P < 0.02). Persistent, stable slowing occurred only in 3/10 non-converters on digoxin (P < 0.05), and two patients developed bradyarrhythmias. QTc was shortened immediately after conversion in all patients. Converters had baseline characteristics similar to those of non-converters. CONCLUSIONS: Intravenous digoxin offers no substantial advantages over placebo in recent onset atrial fibrillation with respect to conversion, and provides weak rate control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ibanez, B., James, S., Agewall, S., Antunes, M. J., Bucciarelli-Ducci, C., Bueno, H., Caforio, A. L. P., Crea, F., Goudevenos, J. A., Halvorsen, S., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx393 · Cited by 9,728
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Neumar, R. W., Otto, C. W., Link, M. S., Kronick, S. L., Shuster, M., Callaway, C. W., Kudenchuk, P. J., Ornato, J. P., McNally, B., Silvers, S. M., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970988 · Cited by 1,634
Metadata
- Authors
- Jordaens, L., Trouerbach, J., Calle, P., Tavernier, R., Derycke, E., Vertongen, P., Bergez, B., & Vandekerckhove, Y.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-04-02
- Volume
- 18
- Issue
- 4
- Pages
- 643-648
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2049040735
- Cited by
- 144
- References
- 0
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conversion of atrial fibrillation to sinus rhythm and rate control by digoxin in comparison to placebo. https://app.cochat.ai/papers/10.1093/oxfordjournals.eurheartj.a015310
- The paper
- Jordaens, L., Trouerbach, J., Calle, P., Tavernier, R., Derycke, E., Vertongen, P., Bergez, B., & Vandekerckhove, Y. (1997). Conversion of atrial fibrillation to sinus rhythm and rate control by digoxin in comparison to placebo. European Heart Journal. https://doi.org/10.1093/oxfordjournals.eurheartj.a015310
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.