Value of ambulatory electrocardiographic monitoring to identify increased risk of sudden death in patients with left ventricular dysfunction and heart failure
The DOI matches its Crossref record.
Abstract
To examine the predictive value of ventricular arrhythmias on ambulatory electrocardiographic (ECG) monitoring, 211 patients with left ventricular dysfunction and congestive heart failure (76% men, age 63 +/- 4 years, left ventricular ejection fraction 0.26 +/- 0.10) were studied. During a follow-up of 21 +/- 11 months, there were 45 cardiac deaths: 22 were due to progressive pump failure and 23 were sudden. Patients with a low left ventricular ejection fraction (< or = 0.27) and ventricular tachycardia on 24 h ECG were at higher risk of dying suddenly and from progressive pump failure (both P < 0.0001). Patients who died suddenly were found to have significantly longer (P = 0.003) and faster (P = 0.029) ventricular tachycardias on their baseline ambulatory ECG, than survivors. This association was not observed in patients who died of progressive pump failure. Therefore, low left ventricular ejection fraction and ventricular tachycardia on 24 h ECG recording predict an increased risk of cardiac mortality. Our results also suggest that longer and faster ventricular tachycardia recorded by 24 h ECG may identify patients at risk of sudden death, a finding which has not been described before.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Inappropriate use of bivariable analysis to screen risk factors for use in multivariable analysis
Sun, G.-W., Shook, T. L., & Kay, G. L. (1996) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(96)00025-x · Cited by 933
B-Type Natriuretic Peptide Predicts Sudden Death in Patients With Chronic Heart Failure
Berger, R., Huelsman, M., Strecker, K., Bojic, A., Moser, P., Stanek, B., & Pacher, R. (2002) · Circulation · doi:10.1161/01.cir.0000016642.15031.34 · Cited by 706
ACC/AHA guidelines for ambulatory electrocardiography
Crawford, M. H., Bernstein, S. J., Deedwania, P. C., DiMarco, J. P., Ferrick, K. J., Garson, A., Green, L. A., Greene, H. L., Silka, M. J., Stone, P. H., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00354-x · Cited by 309
Metadata
- Authors
- SZARÓ, B. M., VAN VELDHUISEN, D. J., CRUNS, H. J. G. M., WIESFELD, A. C. P., HILLEGE, H. L., & LIE, K. I.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-07
- Volume
- 15
- Issue
- 7
- Pages
- 928-933
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2264878993
- Cited by
- 42
- References
- 0
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Value of ambulatory electrocardiographic monitoring to identify increased risk of sudden death in patients with left ventricular dysfunction and heart failure. https://app.cochat.ai/papers/10.1093/oxfordjournals.eurheartj.a060612
- The paper
- SZARÓ, B. M., VAN VELDHUISEN, D. J., CRUNS, H. J. G. M., WIESFELD, A. C. P., HILLEGE, H. L., & LIE, K. I. (1994). Value of ambulatory electrocardiographic monitoring to identify increased risk of sudden death in patients with left ventricular dysfunction and heart failure. European Heart Journal. https://doi.org/10.1093/oxfordjournals.eurheartj.a060612
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.