Noninvasive Quantitative Analysis of Blood Oxygenation in Rat Skeletal Muscle
The DOI matches its Crossref record.
Abstract
Using the isolated perfused rat hindlimb and the fluorocarbon-transfused rat, we have examined the optical characteristics of the rat skeletal muscle in the near-infrared region. The total contribution of myoglobin and cytochromes to the overall absorbance change was less than 10%. Analyzing transmitted light at 700, 730, and 805 nm, we found linear relationships between the absorbance and the hemoglobin concentrations at hematocrit values from 15 to 50% in the inflowing perfusate. Based on the relationship, we determined the ratio of absorption coefficients at 700, 730, and 805 nm of oxy- and deoxy-hemoglobins of blood in the thigh muscle. The values in thigh muscle were significantly smaller than those in hemoglobin solutions for deoxygenated blood. On the other hand, the values in thigh muscle were larger than those in hemoglobin solutions for oxygenated blood. Solving simultaneous equations by the use of these absorption coefficients, we calculated the changes in the contents of oxy-, deoxy-, and total hemoglobins in the anesthetized rat hindlimb under various conditions. The oxygen saturation of blood determined by our optical method in the thigh muscle was very close to that in the vena cava measured directly with a gas analyzer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
DeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00956.2002 · Cited by 369
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“It has been traditionally assumed that Hb is responsible for most of the overall NIRS signal.(51,52) The concept is supported by the observation of strong correlations, observed in different experimental models, between muscle oxygenation values obtained by NIRS and O2 saturation in venous blood (see below).”
BackgroundWilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256
Metadata
- Authors
- Seiyama, A., Hazeki, O., & Tamura, M.
- Venue
- The Journal of Biochemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-03
- Volume
- 103
- Issue
- 3
- Pages
- 419-424
- ISSN
- 0021-924X (ISSN-L)
- 1756-2651
- OpenAlex
- W2173187357
- Cited by
- 149
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Quantitative Analysis of Blood Oxygenation in Rat Skeletal Muscle. https://app.cochat.ai/papers/10.1093/oxfordjournals.jbchem.a122285
- The paper
- Seiyama, A., Hazeki, O., & Tamura, M. (1988). Noninvasive Quantitative Analysis of Blood Oxygenation in Rat Skeletal Muscle. The Journal of Biochemistry. https://doi.org/10.1093/oxfordjournals.jbchem.a122285
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.