The DOI matches its Crossref record.
Successful treatment of haemodialysis catheter-related sepsis without catheter removal
Abstract
Thirty-six Permcath® double-lumen catheters implanted in 36 chronic renal failure patients for haemodialysis treatment were prospectively studied. When catheter-related sepsis was suspected a quantitative blood culture was obtained simultaneously from the catheter and from a peripheral vein. If bacterial colonies in the catheter blood specimen were fourfold greater than identical bacterial colonies in the peripheral blood specimen, the test was considered indicative of catheter sepsis and an empirical antibiotic regimen was begun while the central line remained in situ. Eleven patients suffered 13 episodes of catheter-related sepsis. Staphylococcus epidermidis and Pseudomonas aeruginosa accounted for 77% of the strains isolated. All episodes were successfully treated with vancomycin or ciprofloxacin and yielded negative results on follow-up quantitative blood cultures. Fever subsided within the first 48 h of therapy and no complications occurred. None of these patients required catheter removal for cure of the catheter-related sepsis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Guidelines for the management of intravascular catheter-related infections
Mermel, L. A., Farr, B. M., Sherertz, R. J., Raad, I. I., O'Grady, N., Harris, J. S., & Craven, D. E. (2001) · Clinical Infectious Diseases · doi:10.1086/320001 · Cited by 1,449
Emergence of Vancomycin Resistance in Staphylococcus aureus
Smith, T. L., Pearson, M. L., Wilcox, K. R., Cruz, C., Lancaster, M. V., Robinson-Dunn, B., Tenover, F. C., Zervos, M. J., Band, J. D., White, E., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902183400701 · Cited by 1,088
Metadata
- Authors
- Capdevila, J. A., Segarra, A., Planes, A. M., Ramírez-Arellano, M., Pahissa, A., Piera, L., & Martínez-Vázquez, J. M.
- Venue
- Nephrology Dialysis Transplantation
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-01-01
- Volume
- 8
- Issue
- 3
- Pages
- 231-234
- ISSN
- 0931-0509 (ISSN-L)
- 1460-2385
- OpenAlex
- W1901078584
- Cited by
- 179
- References
- 0
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Successful treatment of haemodialysis catheter-related sepsis without catheter removal. https://app.cochat.ai/papers/10.1093/oxfordjournals.ndt.a092437
- The paper
- Capdevila, J. A., Segarra, A., Planes, A. M., Ramírez-Arellano, M., Pahissa, A., Piera, L., & Martínez-Vázquez, J. M. (1993). Successful treatment of haemodialysis catheter-related sepsis without catheter removal. Nephrology Dialysis Transplantation. https://doi.org/10.1093/oxfordjournals.ndt.a092437
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.