Iron Metabolism in Haemodialysis Patients<subtitle>A STUDY OF THE MANAGEMENT OF IRON THERAPY AND OVERLOAD</subtitle>
The DOI matches its Crossref record.
Abstract
Some dialysis units replace iron losses in patients on maintenance haemodialysis treatment (MHDT) with parenteral iron because of doubts about adequate intestinal iron absorption. Recent experiences in Oxford indicate that this can lead to potentially dangerous iron loading. Sixty-four of 120 MHDT patients had serum ferritin levels >1000 μg/l and there was a good correlation between these levels and the number of years on dialysis. A retrospective post-mortem study of 22 MHDT patients showed significant amounts of iron in liver and spleen and in five cases there was myocardial iron loading. Five MHDT patients with iron loading were given desferrioxamine intravenously at dialysis. Iron was chelated but with some difficulty. Iron absorption, using 59Fe and the total body counter, was found to be similar in both the MHDT patients with iron deficiency (mean ± S.E.M.; 42·5 ± 5·8 per cent) and iron deficient subjects without renal disease (45·3 ± 1·86 per cent). In iron replete MHDT patients iron absorption (8·1 ± 2·6 per cent) did not differ significantly from normal controls (14·9 ± 1·6 per cent) while it was reduced in iron loaded MHDT patients (5·4 ± 0·7 per cent). There was a good correlation between red cell indices and iron stores in MHDT patients and haemoglobin values in 15 iron deficient MHDT patients rose significantly when treated with oral iron. These findings indicate that the control mechanisms which relate iron absorption to body iron stores are intact in patients on MHDT. Oral iron therapy is recommended and can be monitored using red cell indices. Prolonged parenteral iron treatment is unnecessary and potentially dangerous.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Winearls, C., Pippard, M., Downing, M., Oliver, D., Reid, C., & Mary Cotes, P. (1986) · The Lancet · doi:10.1016/s0140-6736(86)92192-6 · Cited by 1,401
Laboratory diagnosis of iron-deficiency anemia: An overview
Guyatt, G. H., Oxman, A. D., Ali, M., Willan, A., McIlroy, W., & Patterson, C. (1992) · Journal of General Internal Medicine · doi:10.1007/bf02598003 · Cited by 564
A randomized controlled study of iron supplementation in patients treated with erythropoietin
Macdougall, I. C., Tucker, B., Thompson, J., Tomson, C. R. V., Baker, L. R. I., & Raine, A. E. G. (1996) · Kidney International · doi:10.1038/ki.1996.487 · Cited by 417
Diagnosis of iron deficiency in chronic renal failure
Fernández-Rodríguez, A. M., Guindeo-Casasús, M. C., Molero-Labarta, T., Domínguez-Cabrera, C., Hortal-Cascón, L., Pérez-Borges, P., Vega-Díaz, N., Saavedra-Santana, P., & Palop-Cubillo, L. (1999) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(99)70079-x · Cited by 126
Iatrogenic Iron Overload in Dialysis Patients at the Beginning of the 21st Century
Rostoker, G., Vaziri, N. D., & Fishbane, S. (2016) · Drugs · doi:10.1007/s40265-016-0569-0 · Cited by 71
Metadata
- Venue
- QJM: An International Journal of Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1979-07
- Volume
- 48
- Issue
- 3
- Pages
- 369-391
- ISSN
- 0033-5622 (ISSN-L)
- 1460-2393
- OpenAlex
- W2411924536
- Cited by
- 105
- References
- 0
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Iron Metabolism in Haemodialysis Patients<subtitle>A STUDY OF THE MANAGEMENT OF IRON THERAPY AND OVERLOAD</subtitle>. https://app.cochat.ai/papers/10.1093/oxfordjournals.qjmed.a067581
- The paper
- Iron Metabolism in Haemodialysis Patients<subtitle>A STUDY OF THE MANAGEMENT OF IRON THERAPY AND OVERLOAD</subtitle>. (1979). QJM: An International Journal of Medicine. https://doi.org/10.1093/oxfordjournals.qjmed.a067581
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.