The Standing Heel-Rise Test for Ankle Plantar Flexion: Criterion for Normal
The DOI matches its Crossref record.
Abstract
BACKGROUND AND PURPOSE: Manual muscle testing with the examiner providing the resistance has long been a standard test of muscle strength. Through the use of extremities acting as levers, clinicians have been able to effectively apply resistance to all muscle groups except the ankle plantar flexors. As a result, a standing heel-rise test that uses body weight as the resistance has been substituted. The number of heel-rises that represent normal plantar-flexor "strength" and the ability of subjects to repeatedly use that "strength" remain unresolved. Because walking is an endurance task, the hypothesis tested by this study was that individuals without known weakness would be able to perform more than the standard recommended one to five standing heel-rises. The purpose of this study was to measure the number of standing heel-rises that individuals without known weakness could accomplish. SUBJECTS: Two hundred three subjects were studied for their ability to do standing heel-rises, as is done when testing plantar-flexion strength using the upright test. There were 122 male subjects and 81 female subjects, ranging in age from 20 to 59 years. METHODS: Each subject was asked to do as many standing heel-rises as he or she could, with careful monitoring of body and limb alignment and of ankle motion, with specific criteria for stopping. RESULTS: The average number of heel-rises was 27.9 (SD = 11.1, minimum = 6, maximum = 70) for all groups and both genders, with no differences between male and female subjects. The lower 99% confidence interval was 25. CONCLUSION AND DISCUSSION: A recommendation is made to change the standard of testing plantar-flexion function, when using the standing heel-rise test, to require 25 repetitions for a grade of Normal. [Lunsford BR, Perry J. The standing heel-rise test for ankle plantar flexion: criterion for normal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Martens, C. R., Denman, B. A., Mazzo, M. R., Armstrong, M. L., Reisdorph, N., McQueen, M. B., Chonchol, M., & Seals, D. R. (2018) · Nature Communications · doi:10.1038/s41467-018-03421-7 · Cited by 588
Injection drug use: an understudied cause of venous disease.
Pieper, B., Kirsner, R. S., Templin, T. N., & Birk, T. J. (2007) · Archives of Dermatology · doi:10.1001/archderm.143.10.1305 · Cited by 40
Komforti, D., Joffe, C., Magras, A., Peller, A., Garbe, E., Garib, R., Trapuzzano, A., Dawson, N., & Stock, M. S. (2021) · Aging Clinical and Experimental Research · doi:10.1007/s40520-020-01596-y · Cited by 25
Metadata
- Authors
- Lunsford, B. R., & Perry, J.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-08-01
- Volume
- 75
- Issue
- 8
- Pages
- 694-698
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2151060602
- Cited by
- 239
- References
- 0
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Standing Heel-Rise Test for Ankle Plantar Flexion: Criterion for Normal. https://app.cochat.ai/papers/10.1093/ptj/75.8.694
- The paper
- Lunsford, B. R., & Perry, J. (1995). The Standing Heel-Rise Test for Ankle Plantar Flexion: Criterion for Normal. Physical Therapy. https://doi.org/10.1093/ptj/75.8.694
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.