Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 477

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Measurements Used to Characterize the Foot and the Medial Longitudinal Arch: Reliability and Validity

Williams, Dorsey S, McClay, Irene S·2000·Physical Therapy

Abstract

Background and Purpose. Abnormality in the structure of the medial longitudinal arch of the foot is commonly thought to be a predisposing factor to injury. The purpose of this investigation was to compare the reliability and validity of several measurements used to characterize various aspects of the foot, including the medial longitudinal arch. Subjects. One hundred two feet (both feet of 51 subjects) were measured to establish a reference database. From this group, a subset of 20 feet (both feet of 10 subjects) was used to determine intertester and intratester reliability. Radiographs of a further subset of 10 feet (right feet of 10 subjects) were used to determine validity. Methods. Five foot measurements were taken in 2 stance conditions: 10% of weight bearing and 90% of weight bearing. Results. Intraclass correlation coefficients (ICCs) for intertester and intratester measurements were between .480 and .995. The most reliable method of characterizing arch type in 10% of weight bearing between testers was dividing navicular height by foot length in 10% of weight bearing. However, this measure yielded highly unreliable measurements in 90% of weight bearing. The most valid measurements were navicular height divided by truncated foot length, navicular height divided by foot length in 10% of weight bearing, and navicular height divided by foot length in 90% of weight bearing. Dorsum height at 50% of foot length divided by truncated foot length showed relatively high intertester reliability (ICC=.811 in 10% of weight bearing, ICC=.848 in 90% of weight bearing) and validity (ICC=.844 in 10% of weight bearing, ICC=.851 in 90% of weight bearing). Conclusion and Discussion. These data suggest that, of the measures tested, the most reliable and valid method of clinically assessing arch height across 10% and 90% of weight bearing was dividing the dorsum height at 50% of foot length by truncated foot length.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ptj/80.9.864

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 477

Metadata

Authors
Williams, D. S., & McClay, I. S.
Venue
Physical Therapy
Published
2000-09-01
Volume
80
Issue
9
Pages
864-871
ISSN
  • 0031-9023 (ISSN-L)
  • 1538-6724
OpenAlex
W2118031278
Cited by
477
References
1
FWCI
3.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurements Used to Characterize the Foot and the Medial Longitudinal Arch: Reliability and Validity. https://app.cochat.ai/papers/10.1093/ptj/80.9.864
The paper
Williams, D. S., & McClay, I. S. (2000). Measurements Used to Characterize the Foot and the Medial Longitudinal Arch: Reliability and Validity. Physical Therapy. https://doi.org/10.1093/ptj/80.9.864

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.