Material Properties of Thera-Band Tubing
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background and Purpose. Thera-Band Tubing has been used in rehabilitation to provide resistance for exercise and splinting. However, the forces required to stretch the tubing have not been thoroughly quantified. Therefore, the therapist cannot assess, with certainty, how much force is applied when using a given length and type of Thera-Band Tubing. The purpose of this study was to quantify the material properties of Thera-Band Tubing. Methods. Force versus percentage of strain for all types of Thera-Band Tubing was measured during elongation in a mechanical testing machine. Results. The material is very compliant and displays nonlinear behavior in the initial stretching phase and linear behavior after 50% elongation. Discussion and Conclusion. From the data obtained in this project, plots that can provide the therapist with information about the forces needed for exercises with Thera-Band Tubing were generated. These data should allow therapists to make better choices about which size of tubing to use for each patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efficacy of a home-based training program for older adults using elastic tubing
Mikesky, A. E., Topp, R., Wigglesworth, J. K., Harsha, D. M., & Edwards, J. E. (1994) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00392037 · Cited by 139
Cited by
Andersen, L. L., Andersen, C. H., Mortensen, O. S., Poulsen, O. M., Bjørnlund, I. B. T., & Zebis, M. K. (2010) · Physical Therapy · doi:10.2522/ptj.20090167 · Cited by 256
Colado, J. C., & Triplett, N. T. (2008) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31817ae67a · Cited by 180
“This is due to the different elongation coefficients of the bands and their modification during use, suggesting an urgent need to find specific equations for each type of elastic band (39), as well as evaluating them when it comes to comparing their applications (29).”
BackgroundKwon, H. R., Han, K. A., Ku, Y. H., Ahn, H. J., Koo, B.-K., Kim, H. C., & Min, K. W. (2010) · Korean Diabetes Journal · doi:10.4093/kdj.2010.34.2.101 · Cited by 108
“In addition, it has been proven to be an effective exercise modality for enhancing muscle and physical strength without placing excessive stress on each joint or muscle [14,15].”
BackgroundMuscle fatigue induced by two different resistances: Elastic tubing versus weight machines
Melchiorri, G., & Rainoldi, A. (2011) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2011.07.015 · Cited by 82
Southern, W. M., Ryan, T. E., Reynolds, M. A., & McCully, K. (2014) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2013-0347 · Cited by 80
“The material properties of the Thera-Band have been previously reported (Patterson et al. 2001).”
Method
Metadata
- Authors
- Patterson, R. M., Stegink Jansen, C. W., Hogan, H. A., & Nassif, M. D.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-08-01
- Volume
- 81
- Issue
- 8
- Pages
- 1437-1445
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2115194073
- Cited by
- 123
- References
- 1
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Material Properties of Thera-Band Tubing. https://app.cochat.ai/papers/10.1093/ptj/81.8.1437
- The paper
- Patterson, R. M., Stegink Jansen, C. W., Hogan, H. A., & Nassif, M. D. (2001). Material Properties of Thera-Band Tubing. Physical Therapy. https://doi.org/10.1093/ptj/81.8.1437
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.