The DOI matches its Crossref record.
Reliability of a Measurement of Neck Flexor Muscle Endurance
Abstract
Background and Purpose. Neck flexor muscle endurance has been negatively correlated with cervical pain and dysfunction. The purposes of this study were to determine rater reliability in subjects both withand without neck pain and to determine whether there was a difference in neck flexor muscle endurance between the 2 groups. Subjects. Forty-one subjects with and without neck pain were enrolled in this repeated-measures reliability study. Methods. Two raters used an isometric neck retraction test to assess neck flexor muscle endurancefor all subjects during an initial session, and subjects without neck pain returned for testing 1 week later. Results. For the group without neck pain, intrarater reliability was good to excellent (intraclass correlation coefficient [ICC(3,1)]=.82–.91), and interrater reliability was moderate to good (ICC[2,1]=.67–.78). The associated standard error of measurement (SEM) ranged from 8.0 to 11.0 seconds and from 12.6 to 15.3 seconds, respectively. For the group with neck pain, interrater reliability was moderate(ICC[2,1]=.67, SEM=11.5). Neck flexor muscle endurance test results for the group without neck pain (X̄=38.95 seconds, SD=26.4) and the group with neck pain (X̄=24.1 seconds, SD=12.8) were significantly different. Discussion and Conclusion. Reliability coefficients differed between the 2 groups and ranged from moderate to excellent and improved after the first test session. The interrater reliability of data obtained with the neck flexor muscle endurance test in people with neck pain must be improved in order for clinicians to distinguish a clinically meaningful change from measurement error. Neck flexor muscle endurance was both statistically and clinically greater for subjects without neck pain than for those with neck pain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Assessment of the Deep Cervical Flexor Muscles: The Craniocervical Flexion Test
Jull, G. A., O'Leary, S. P., & Falla, D. L. (2008) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2008.08.003 · Cited by 485
Cleland, J. A., Childs, J. D., Fritz, J. M., Whitman, J. M., & Eberhart, S. L. (2007) · Physical Therapy · doi:10.2522/ptj.20060155 · Cited by 318
Self-citationNeck muscle endurance and head posture: A comparison between adolescents with and without neck pain
Oliveira, A. C., & Silva, A. G. (2016) · Manual Therapy · doi:10.1016/j.math.2015.10.002 · Cited by 85
Biomechanical measures in participants with shoulder pain: Intra-rater reliability
Michener, L. A., Elmore, K. A., Darter, B. J., & Timmons, M. K. (2016) · Manual Therapy · doi:10.1016/j.math.2015.10.011 · Cited by 18
Metadata
- Authors
- Harris, K. D., Heer, D. M., Roy, T. C., Santos, D. M., Whitman, J. M., & Wainner, R. S.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-12-01
- Volume
- 85
- Issue
- 12
- Pages
- 1349-1355
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2167009818
- Cited by
- 243
- References
- 0
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of a Measurement of Neck Flexor Muscle Endurance. https://app.cochat.ai/papers/10.1093/ptj/85.12.1349
- The paper
- Harris, K. D., Heer, D. M., Roy, T. C., Santos, D. M., Whitman, J. M., & Wainner, R. S. (2005). Reliability of a Measurement of Neck Flexor Muscle Endurance. Physical Therapy. https://doi.org/10.1093/ptj/85.12.1349
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.