Continuous-Scale Physical Functional Performance Test: Validity, Reliability, and Sensitivity of Data for the Short Version
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background and Purpose. The Continuous-Scale Physical Functional Performance Test (CS-PFP) can be used to obtain valid, reliable, and sensitive measurements of physical functional capacity. This test requires a fixed laboratory space and approximately 1 hour to administer. This study was carried out in 4 steps, or substudies, to develop and validate a short, community-based version (PFP-10) that requires less space and equipment than the CS-PFP. Subjects and Methods. Retrospective data (n=228) and prospective data (n=91) on men and women performing the CS-PFP or the PFP-10 are reported. A 12-week exercise program was used to examine sensitivity to change. Data analyses were done using paired t-test, Pearson correlation, intraclass correlation coefficient (ICC), and delta index (DI) procedures. Results. The PFP-10 total score and 4 of the 5 domain scores were statistically similar (within 3%) to those of the CS-PFP. The PFP-10 upper-body strength domain score was 17% lower, but was highly correlated (ICC=.97). Community and established laboratory PFP-10 scores were similar (ICC=.85–.97). The PFP-10 also is sensitive to change (DI=.21–.54). Discussion and Conclusion. The PFP-10 yields valid, reliable, and sensitive measurements and can be confidently substituted for the CS-PFP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-, six-, and 12-minute walking tests in respiratory disease.
Butland, R. J., Pang, J., Gross, E. R., Woodcock, A. A., & Geddes, D. M. (1982) · BMJ · doi:10.1136/bmj.284.6329.1607 · Cited by 1,668
Effect of strength and power training on physical function in community-dwelling older adults.
Miszko, T. A., Cress, M. E., Slade, J. M., Covey, C. J., Agrawal, S. K., & Doerr, C. E. (2003) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/58.2.m171 · Cited by 391
Self-citationPinsky, J. L., Jette, A. M., Branch, L. G., Kannel, W. B., & Feinleib, M. (1990) · American Journal of Public Health · doi:10.2105/ajph.80.11.1363 · Cited by 214
Cited by
Rikli, R. E., & Jones, C. J. (2013) · The Gerontologist · doi:10.1093/geront/gns071 · Cited by 1,101
Moss, M., Nordon-Craft, A., Malone, D., Van Pelt, D., Frankel, S. K., Warner, M. L., Kriekels, W., McNulty, M., Fairclough, D. L., & Schenkman, M. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201505-1039oc · Cited by 349
Self-citationVikberg, S., Sörlén, N., Brandén, L., Johansson, J., Nordström, A., Hult, A., & Nordström, P. (2019) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2018.09.011 · Cited by 261
Balachandran, A., Krawczyk, S. N., Potiaumpai, M., & Signorile, J. F. (2014) · Experimental Gerontology · doi:10.1016/j.exger.2014.09.016 · Cited by 151
“Gait speed has been shown to contribute to most, but not all, of the explanatory power of SPPB and has been established as a primary functional outcome in systematic reviews (Cress et al., 2005; Sweet et al., 2004).”
BackgroundMethodAdunsky, A., Chandler, J., Heyden, N., Lutkiewicz, J., Scott, B. B., Berd, Y., Liu, N., & Papanicolaou, D. A. (2011) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2010.10.004 · Cited by 67
“The PFP-10 summary scores were determined in accordance with published procedures (Cress et al., 1999, 2005).”
BackgroundMethod
Metadata
- Authors
- Cress, M. E., Petrella, J. K., Moore, T. L., & Schenkman, M. L.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-04-01
- Volume
- 85
- Issue
- 4
- Pages
- 323-335
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2133596564
- Cited by
- 97
- References
- 3
- FWCI
- 14.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous-Scale Physical Functional Performance Test: Validity, Reliability, and Sensitivity of Data for the Short Version. https://app.cochat.ai/papers/10.1093/ptj/85.4.323
- The paper
- Cress, M. E., Petrella, J. K., Moore, T. L., & Schenkman, M. L. (2005). Continuous-Scale Physical Functional Performance Test: Validity, Reliability, and Sensitivity of Data for the Short Version. Physical Therapy. https://doi.org/10.1093/ptj/85.4.323
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.