CoChat

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Inter-examiner reproducibility of tests and criteria for generalized joint hypermobility and benign joint hypermobility syndrome

Juul-Kristensen, B., Rogind, H., Jensen, D. V., Remvig, L. · 2007 · Rheumatology

Abstract

OBJECTIVE: To test the reproducibility of tests and criteria for generalized joint hypermobility (GJH) and benign joint hypermobility syndrome (BJHS). METHODS: A standardized protocol for clinical reproducibility studies was followed using a three-phase study (with a training, an overall agreement and a test phase). An overall agreement of at least 0.80 was required to proceed to the test phase. Phases 1, 2 and 3 used 14 patients (with varying degrees of hypermobility), 20 patients (50% cases) and 40 patients (50% cases), respectively. The inclusion criterion for cases was hypermobility (patients with Ehlers-Danlos Syndrome or BJHS) and for controls, non-hypermobility (patients with shoulder and/or back pain); patients were selected from patients' files (phases 1 and 2) or included consecutively from our outpatient clinic (phase 3). RESULTS: The overall agreement in phase 2 was 0.95 for GJH and 0.90 for BJHS. Reproducibility for diagnosing GJH and BJHS in phase 3 showed kappa values of 0.74 and 0.84, respectively. Kappa in the Beighton tests for diagnosing GJH (currently or historically) was generally above 0.80, except for the fifth fingers and elbows (> or = 0.60). In the Brighton tests for diagnosing BJHS, kappa was above 0.73, except for the skin signs (0.63). Lowest kappa was found in the Rotès-Quérol tests, where it was > or = 0.57, except for the right shoulder (0.31). CONCLUSION: We found a good-to-excellent reproducibility of tests and criteria for GJH and BJHS. Future research on the validity of the tests and criteria for joint hypermobility is urgently needed.

Overview

Integrity signals

Registry

Crossref · 10.1093/rheumatology/kem290

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Cited by

See all 299

Metadata

Authors
Juul-Kristensen, B., Rogind, H., Jensen, D. V., & Remvig, L.
Affiliations
Frederiksberg Hospital (DK)
Venue
Rheumatology
Published
2007-08-05
Volume
46
Issue
12
Pages
1835-1841
ISSN
  • 1462-0324 (ISSN-L)
  • 1462-0332
OpenAlex
W2128602425
Cited by
299
References
24
Citations by year
2026: 14 · 2025: 2 · 2024: 15 · 2023: 13 · 2022: 17 · 2021: 18 · 2020: 28 · 2019: 14 · 2018: 20 · 2017: 23 · 2016: 25 · 2015: 20 · 2014: 23 · 2013: 23 · 2012: 15
FWCI
3.21
Type
journal article
Language
en
Open access
closed
Locations
  • Lara D. Veeken (publishedVersion)
  • PubMed (publishedVersion)
Funders
Fonds National de la Recherche Luxembourg
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Connective tissue disorders research
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Musculoskeletal pain and rehabilitation
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
Keywords
generalized joint hypermobility, benign joint hypermobility syndrome, interobserver reproducibility, Brighton criteria, Ehlers-Danlos syndrome, diagnostic criteria, interobserver agreement
MeSH terms
Adolescent, Adult, Aged, Aged, 80 and over, Female, Humans, Joint Diseases, Joint Instability, Male, Middle Aged, Probability, Risk Factors, Sensitivity and Specificity, Severity of Illness Index, Reproducibility of Results, Observer Variation, Confidence Intervals, Range of Motion, Articular, Statistics, Nonparametric, Arthrometry, Articular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inter-examiner reproducibility of tests and criteria for generalized joint hypermobility and benign joint hypermobility syndrome. https://app.cochat.ai/papers/10.1093/rheumatology/kem290
The paper
Juul-Kristensen, B., Rogind, H., Jensen, D. V., & Remvig, L. (2007). Inter-examiner reproducibility of tests and criteria for generalized joint hypermobility and benign joint hypermobility syndrome. Rheumatology. https://doi.org/10.1093/rheumatology/kem290

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.