Test-Retest Reliability of the MSLT
The DOI matches its Crossref record.
Abstract
The test-retest reliability of the Multiple Sleep Latency Test (MSLT) was evaluated in 14 healthy normal subjects. Each slept a single night in the laboratory (8 h time in bed) and received the MSLT the following day (1000, 1200, 1400, and 1600 h) on two occasions separated by 4-14 months. Mean sleep latency (four tests) was highly reliable from MSLT to MSLT (r = 0.97, p less than 0.001). The test-retest reliability did not change as a function of the interval of time between tests or as a function of the level of sleepiness (range = 4-20 min) within the population. However, as the number of tests comprising the MSLT was reduced below three, the reliability was reduced such that only 50% or less of the variance could be predicted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
“…while lying down in a non stimulating envi ronment The MSLT has a reasonably high test-retest reliability over periods of months in normal subjects (4 Assuming the same reliability holds tme for pa tients, the MSLT must be considered the standard method for measuring their chronic daytime sleepi…”
MethodJohns, M. W. (2000) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2000.00177.x · Cited by 824
Sleepiness in Different Situations Measured by the Epworth Sleepiness Scale
Johns, M. W. (1994) · Sleep · doi:10.1093/sleep/17.8.703 · Cited by 734
Distinguishing sleepiness and fatigue: focus on definition and measurement
Shen, J., Barbera, J., & Shapiro, C. M. (2006) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2005.05.004 · Cited by 687
The Clinical Use of the MSLT and MWT
Arand, D., Bonnet, M., Hurwitz, T., Mitler, M., Rosa, R., & Sangal, R. B. (2005) · Sleep · doi:10.1093/sleep/28.1.123 · Cited by 389
Individual Differences in Adult Human Sleep and Wakefulness: Leitmotif for a Research Agenda
van Dongen, H. P. A., Vitellaro, K. M., & Dinges, D. F. (2005) · Sleep · doi:10.1093/sleep/28.4.479 · Cited by 339
Validation of a Chinese version of the Epworth sleepiness scale
Chen, N.-H., Johns, M. W., Li, H.-Y., Chu, C.-C., Liang, S.-C., Shu, Y.-H., Chuang, M.-L., & Wang, P.-C. (2002) · Quality of Life Research · doi:10.1023/a:1020818417949 · Cited by 337
The Clinical Use of the Multiple Sleep Latency Test
(1992) · Sleep · doi:10.1093/sleep/15.3.268 · Cited by 273
Measurements of sleepiness and fatigue
Shahid, A., Shen, J., & Shapiro, C. M. (2010) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2010.04.001 · Cited by 227
“97) [13].”
Cutaneous warming promotes sleep onset
Raymann, R. J. E. M., Swaab, D. F., & Van Someren, E. J. W. (2005) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00492.2004 · Cited by 201
Krahn, L. E., Arand, D. L., Avidan, A. Y., Davila, D. G., DeBassio, W. A., Ruoff, C. M., & Harrod, C. G. (2021) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.9620 · Cited by 177
Effects of caffeine on alertness
Zwyghuizen-Doorenbos, A., Roehrs, T. A., Lipschutz, L., Timms, V., & Roth, T. (1990) · Psychopharmacology · doi:10.1007/bf02245786 · Cited by 172
Self-citation
Metadata
- Authors
- Zwyghuizen-Doorenbos, A., Roehrs, T., Schaefer, M., & Roth, T.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1988-09
- Volume
- 11
- Issue
- 6
- Pages
- 562-565
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2409984749
- Cited by
- 108
- References
- 0
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.