The Reliability and Functional Validity of Visual and Semiautomatic Sleep/Wake Scoring in the Møll-Wistar Rat
The DOI matches its Crossref record.
Abstract
The present paper has three major objectives: first, to document the reliability of a published criteria set for sleep/wake scoring in the rat; second, to develop a computer algorithm implementation of the criteria set; and third, to document the reliability and functional validity of the computer algorithm for sleep/wake scoring. The reliability of the visual criteria was assessed by letting two raters separately score 8 hours of polygraph records from the light period from five rats (14,040 10-second scoring epochs). Scored stages were waking, slow-wave sleep-1, slow-wave sleep-2, transition type sleep and rapid eye movement (REM) sleep. The visual criteria had good interrater reliability [Cohen's kappa (kappa) = 0.68], with 92.6% agreement on the waking/nonrapid eye movement (NREM) sleep/REM sleep distinction (kappa = 0.89). This indicated that the criteria allow separate raters to independently classify sleep/wake stages with very good agreement. An independent group of 10 rats was used for development of an algorithm for semiautomatic computer scoring. A close implementation of the visual criteria was chosen. The algorithm was based on power spectral densities from two electroencephalogram (EEG) leads and on electromyogram (EMG) activity. Five 2-second fast Fourier transform (FFT) epochs from each EEG/EMG lead per 10-second sleep/wake scoring epoch were used to take the spatial and temporal context into account. The same group of five rats used in visual scoring was used to appraise reliability of computerized scoring. The computer score was compared with the visual score for each rater. There was a lower agreement (kappa = 0.57 and 0.62 for the two raters) than in interrater visual scoring [percent agreement 87.7 and 89.1% (kappa = 0.82 and 0.84) in the waking/NREM sleep/REM sleep distinction]. Subsequently, the computer scores of the raters were compared. The interrater reliability was better than the interrater reliability for visual scoring (kappa = 0.75), with 92.4% agreement for the waking/NREM sleep/REM sleep distinction (kappa = 0.89). The computer scoring algorithm was applied to data from a third independent group of rats (n = 6) from an acoustical stimulus arousal threshold experiment, to assess the functional validity of the scoring directly with respect to arousal threshold. The computer algorithm scoring performed as well as the original visual sleep/wake stage scoring. This indicated that the lower intrarater reliability did not have a significant negative influence on the functional validity of the sleep/wake score.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The hippocampus is crucial for forming non-hippocampal long-term memory during sleep
Sawangjit, A., Oyanedel, C. N., Niethard, N., Salazar, C., Born, J., & Inostroza, M. (2018) · Nature · doi:10.1038/s41586-018-0716-8 · Cited by 208
Sleep-stage-specific regulation of cortical excitation and inhibition
Niethard, N., Hasegawa, M., Itokazu, T., Oyanedel, C. N., Born, J., & Sato, T. R. (2016) · Current Biology · doi:10.1016/j.cub.2016.08.035 · Cited by 140
Transcranial slow oscillation stimulation during sleep enhances memory consolidation in rats
Binder, S., Berg, K., Gasca, F., Lafon, B., Parra, L. C., Born, J., & Marshall, L. (2014) · Brain Stimulation · doi:10.1016/j.brs.2014.03.001 · Cited by 74
Temporal associations between sleep slow oscillations, spindles and ripples
Oyanedel, C. N., Durán, E., Niethard, N., Inostroza, M., & Born, J. (2020) · European Journal of Neuroscience · doi:10.1111/ejn.14906 · Cited by 71
Sleep stage dynamics in neocortex and hippocampus
Durán, E., Oyanedel, C. N., Niethard, N., Inostroza, M., & Born, J. (2018) · Sleep · doi:10.1093/sleep/zsy060 · Cited by 52
Karashima, A., Nakao, M., Honda, K., Iwasaki, N., Katayama, N., & Yamamoto, M. (2004) · Neuroscience Research · doi:10.1016/j.neures.2004.07.007 · Cited by 44
Two distinct ways to form long-term object recognition memory during sleep and wakefulness
Sawangjit, A., Harkotte, M., Oyanedel, C. N., Niethard, N., Born, J., & Inostroza, M. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2203165119 · Cited by 28
“Sleep stage classification was performed offline by an experienced experimenter using 10-s epochs according to standard criteria (63).”
Method
Metadata
- Authors
- Neckelmann, D., Olsen, Ø. E., Fagerland, S., & Ursin, R.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-03
- Volume
- 17
- Issue
- 2
- Pages
- 120-131
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2397072832
- Cited by
- 61
- References
- 0
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.