Using Self-Reported Questionnaire Data to Prioritize OSA Patients for Polysomnography
The DOI matches its Crossref record.
Abstract
Many laboratories have large numbers of patients with suspected obstructive sleep apnea (OSA) waiting to be tested. We assessed the use of simple clinical data to detect those patients with an apnea index <20 (low AI) who could be studied less emergently. Using questionnaires completed by patients prior to evaluation, we collected data on 354 consecutive patients (281 males, 73 females; mean age 48.6 years) referred for OSA and assessed with polysomnography (PSG). The questionnaires included the Epworth sleepiness scale (ESS), height, weight, age, and a history of observed apnea. Analysis of receiver operating characteristics curves revealed that both body mass index (BMI) [area under curve = 0.7258, standard error (SE) = 0.03, p < 0.01] and ESS (area under curve = 0.5581, SE = 0.03, p = 0.03) were significantly better than chance alone in detecting people with AI < 20. ESS < or =12 was found in 37.9% of the subjects but 39.6% of those expected to have a low AI using ESS had an AI > or =20. A BMI < or =28 was found in 24.9% of the subjects; 14.8% of those expected to have a low AI using BMI had an AI > or =20. Combining these variables improved accuracy but resulted in smaller groups; a cut-off of ESS < or =12 and BMI < or =28 resulted in a group of 33 (9.3% of subjects), only two (6%) of whom were falsely called low AI. Adding to this the fact that apnea had not been observed resulted in a group of nine patients (2.5% of subjects), none of whom had an AI > or =20. Thus there is a tradeoff; the more variables used, the greater the accuracy but the smaller the percent of cases selected to have low AI. However, in laboratories with hundreds of patients waiting to be tested, any procedure better than chance to help prioritize patients seems worthwhile.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
A systematic review of screening questionnaires for obstructive sleep apnea
Abrishami, A., Khajehdehi, A., & Chung, F. (2010) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-010-9280-x · Cited by 581
The Epworth Sleepiness Scale may not reflect objective measures of sleepiness or sleep apnea
Chervin, R. D., & Aldrich, M. S. (1999) · Neurology · doi:10.1212/wnl.52.1.125 · Cited by 395
German Version of the Epworth Sleepiness Scale
Bloch, K. E., Schoch, O. D., Zhang, J. N., & Russi, E. W. (1999) · Respiration · doi:10.1159/000029408 · Cited by 296
Clinical presentations of obstructive sleep apnea syndrome
Skomro, R. P., & Kryger, M. H. (1999) · Progress in Cardiovascular Diseases · doi:10.1053/pcad.1999.0410331 · Cited by 78
Self-citation
Metadata
- Authors
- Pouliot, Z., Peters, M., Neufeld, H., & Kryger, M. H.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-03
- Volume
- 20
- Issue
- 3
- Pages
- 232-236
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W1653487
- Cited by
- 54
- References
- 0
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using Self-Reported Questionnaire Data to Prioritize OSA Patients for Polysomnography. https://app.cochat.ai/papers/10.1093/sleep/20.3.232
- The paper
- Pouliot, Z., Peters, M., Neufeld, H., & Kryger, M. H. (1997). Using Self-Reported Questionnaire Data to Prioritize OSA Patients for Polysomnography. Sleep. https://doi.org/10.1093/sleep/20.3.232
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.