Air Leaking Through the Mouth During Nocturnal Nasal Ventilation: Effect on Sleep Quality
The DOI matches its Crossref record.
Abstract
Air leaking through the mouth has been reported in kyphoscoliotic patients receiving nasal ventilation via volume-limited ventilators. This study accessed the frequency of occurrence and effect on sleep quality of air leaking through the mouth during nocturnal nasal ventilation in patients with chest wall and neuromuscular disease using pressure-limited ventilation. Overnight and daytime polysomnography was performed in six stable experienced users of nocturnal nasal noninvasive positive-pressure ventilation (NPPV) who had chronic respiratory failure due to neuromuscular disease or chest wall deformity. All patients used the BiPAP S/T-D ventilatory support system (Respironics, Inc., Murrysville, PA). Measures included sleep scoring, leak quantitation, diaphragm and submental electromyograms (EMGs), and tidal and leak volumes. All patients had air leaking through the mouth for the majority of sleep. Sleep quality was diminished because of poor sleep efficiency and reduced percentages of slow-wave and rapid eye movement (REM) sleep. Air leaking through the mouth was associated with frequent arousals during stages 1 and 2 and REM sleep that contributed to sleep fragmentation, but arousals were infrequent during slow-wave sleep. Despite prevalent leaking, oxygenation was well maintained in all but one patient. Patients used a-combination of passive and active mechanisms to control air leaking. Although nasal ventilation improves nocturnal hypoventilation and symptoms in patients with restrictive thoracic disorders, air leaking through the mouth is very common during use. The leaking is associated with frequent arousals during lighter stages of sleep that interfere with progression to deeper stages, compromising sleep quality. Portable pressure-limited ventilators compensate for leaks, maintaining ventilation and oxygenation, but further studies are needed to determine which interfaces and ventilator techniques best control air leaking and optimize sleep quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
MEHTA, S., & HILL, N. S. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.2.9906116 · Cited by 890
Self-citationDefinition, discrimination, diagnosis and treatment of central breathing disturbances during sleep
Randerath, W., Verbraecken, J., Andreas, S., Arzt, M., Bloch, K. E., Brack, T., Buyse, B., De Backer, W., Eckert, D. J., Grote, L., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00959-2016 · Cited by 354
NPPV Titration Task Force of the American Academy of Sleep Medicine, Berry, R. B., Chediak, A., Brown, L. K., Finder, J., Gozal, D., Iber, C., Kushida, C. A., Morgenthaler, T., Rowley, J. A., et al. (2010) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27941 · Cited by 315
Rowland, S., Aiyappan, V., Hennessy, C., Catcheside, P., Chai-Coezter, C. L., McEvoy, R. D., & Antic, N. A. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6892 · Cited by 105
Pressure-Relief Continuous Positive Airway Pressure vs Constant Continuous Positive Airway Pressure
Nilius, G., Happel, A., Domanski, U., & Ruhle, K.-H. (2006) · Chest · doi:10.1378/chest.130.4.1018 · Cited by 99
Metadata
- Authors
- Meyer, T. J., Pressman, M. R., Benditt, J., McCool, F. D., Millman, R. P., Natarajan, R., & Hill, N. S.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-07
- Volume
- 20
- Issue
- 7
- Pages
- 561-569
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W36698439
- Cited by
- 131
- References
- 0
- FWCI
- 1.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Air Leaking Through the Mouth During Nocturnal Nasal Ventilation: Effect on Sleep Quality. https://app.cochat.ai/papers/10.1093/sleep/20.7.561
- The paper
- Meyer, T. J., Pressman, M. R., Benditt, J., McCool, F. D., Millman, R. P., Natarajan, R., & Hill, N. S. (1997). Air Leaking Through the Mouth During Nocturnal Nasal Ventilation: Effect on Sleep Quality. Sleep. https://doi.org/10.1093/sleep/20.7.561
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.