CoChat

A Sleep Laboratory Evaluation of an Automatic Positive Airway Pressure System for Treatment of Obstructive Sleep Apnea

Behbehani, Khosrow, Yen, Fu-Chung, Lucas, Edgar A., Burk, John R. · 1998 · Sleep
Cited by 28

The DOI matches its Crossref record.

Abstract

STUDY OBJECTIVES: This paper compares the performance of an experimental nasal positive airway pressure device that automatically adjusts the level of applied pressure (APAP) with the performance of a conventional continuous positive airway pressure (CPAP) in a sleep laboratory study. DESIGN: In a randomized sequence, conventional CPAP therapy was applied for 1 night (CPAP night) and APAP therapy the following night (APAP night). SETTING: The study was conducted in an accredited sleep disorders center. PATIENTS OR PARTICIPANTS: Twenty-six men and 5 women between the ages of 35 to 73 (51 +/- 9.6) years with body mass index 35.82 +/- 8.35 (kg/m2) who were diagnosed (using standard nocturnal polysomnography [NPSG] methods) as having OSA syndrome were studied. The subjects were treated with conventional CPAP for approximately 8 (7.79 +/- 3.16) weeks at home prior to their participation in this study. MEASUREMENTS AND RESULTS: All standard polysomnography data and nasal mask pressures were recorded using a computer-based data acquisition system. Sleep and respiratory data were scored by a registered polysomnographer. The mean apnea-hypopnea index (AHI) for subjects for the NPSG night was 55.2 +/- 33.7. It dropped to 4.2 +/- 3.8 for the CPAP night and to 5.4 +/- 5.4 for the APAP night. There was no significant (p = 0.05) difference between mean AHI indices, sleep stages, sleep stage shifts, and snore arousals for CPAP night and APAP night. However, all the measures showed significant (p = 0.05) improvement over NPSG night. The mean of APAP applied pressure (8.4 +/- 3.3 cm H2O) was significantly (p = 0.05) lower than the prescribed pressure (11.5 +/- 3.1 cm H2O), but there was no significant (p = 0.05) difference between the maximum APAP applied pressure (12.8 +/- 4.3 cm H2O) and the prescribed pressure (11.5 +/- 3.1 cm H2O). All mean comparison tests were carried out using two-tailed statistics. CONCLUSIONS: APAP appears to be as effective as CPAP in treating OSA patients. APAP delivers the same level of therapy as CPAP, but it reduces the average airway pressure while providing needed peak pressures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/21.5.485

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 28

Metadata

Authors
Behbehani, K., Yen, F.-C., Lucas, E. A., & Burk, J. R.
Venue
Sleep
Published
1998-08
Volume
21
Issue
5
Pages
485-491
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2412375709
Cited by
28
References
0
FWCI
0.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Sleep Laboratory Evaluation of an Automatic Positive Airway Pressure System for Treatment of Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1093/sleep/21.5.485
The paper
Behbehani, K., Yen, F.-C., Lucas, E. A., & Burk, J. R. (1998). A Sleep Laboratory Evaluation of an Automatic Positive Airway Pressure System for Treatment of Obstructive Sleep Apnea. Sleep. https://doi.org/10.1093/sleep/21.5.485

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.