Utility of Home Oximetry as a Screening Test for Patients with Moderate to Severe Symptoms of Obstructive Sleep Apnea
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To determine the value of home oximetry as a screening test in patients with moderate to severe symptoms of obstructive sleep apnea (OSA). DESIGN: Retrospective, observational study. SETTING: The Sleep Unit of a tertiary referral, university hospital. PATIENTS: 116 patients referred for evaluation of moderate to severe symptoms of OSA in which both home oximetry and polysomnography (PSG) were performed. INTERVENTIONS: NA. RESULTS: Three numerical oximetry indices were evaluated: average of desaturations > or =4% and average of resaturations > or =3% per hour of analysis time (DI4% and RI3%, respectively); and cumulative percentages of time spent at saturations below 90% (CT90%). A qualitative assessment was also performed. Oximetry indices were compared with apnea/hypopnea index (AHI) by simple linear regression and Bland-Altman analyses. Optimal cut-off points, in terms of sensitivity and specificity, for the oximetry indices were searched using ROC analysis, at an AHI threshold of > or =10. The correlation between AHI and the desaturation indices was r = 0.50 for CT90%, r = 0.60 for DI4%, and r = 0.58 for RI3%. No bias was found between PSG and oximetry indices in Bland-Altman plots. Neither the numerical indices nor the qualitative analysis achieved an adequate (>0.8) area under the ROC curve. A CT90% <0.79 excluded OSA with 84% sensitivity. A DI4% > or =31.4 or a RI3% > or =40.5 diagnosed OSA with 97% specificity. Using these values, 38% of the patients would have been correctly classified by oximetry alone, 10% would have been incorrectly classified, and 50% could not have been classified with certainty. Eleven (15%) OSA patients would have been missed by oximetry. CONCLUSIONS: Correlation between home oximetry and PSG was not high. Oximetry was more useful to confirm than to exclude OSA in our study. Qualitative assessment was not better than numerical analysis. The greatest value of oximetry in this setting seems to be as a tool to rapidly recognize and treat more severe OSA patients in waiting list for PSG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Overnight Pulse Oximetry for Sleep-Disordered Breathing in Adults
Netzer, N., Eliasson, A. H., Netzer, C., & Kristo, D. A. (2001) · Chest · doi:10.1378/chest.120.2.625 · Cited by 311
Obstructive sleep apnoea and perioperative complications in bariatric patients
Weingarten, T. N., Flores, A. S., McKenzie, J. A., Nguyen, L. T., Robinson, W. B., Kinney, T. M., Siems, B. T., Wenzel, P. J., Sarr, M. G., Marienau, M. S., et al. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aeq290 · Cited by 146
Diagnosis of Obstructive Sleep Apnea Syndrome and Its Outcomes With Home Portable Monitoring
de Oliveira, A. C. T., Martinez, D., Vasconcelos, L. F. T., Cadaval Gonçalves, S., do Carmo Lenz, M., Costa Fuchs, S., Gus, M., de Abreu-Silva, E. O., Beltrami Moreira, L., & Danni Fuchs, F. (2009) · Chest · doi:10.1378/chest.08-1859 · Cited by 129
Metadata
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-10-01
- Volume
- 22
- Issue
- 7
- Pages
- 932-7
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W204361854
- Cited by
- 123
- References
- 0
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Utility of Home Oximetry as a Screening Test for Patients with Moderate to Severe Symptoms of Obstructive Sleep Apnea. https://app.cochat.ai/papers/10.1093/sleep/22.7.932
- The paper
- Utility of Home Oximetry as a Screening Test for Patients with Moderate to Severe Symptoms of Obstructive Sleep Apnea. (1999). Sleep. https://doi.org/10.1093/sleep/22.7.932
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.