The Roles of Vertex Sharp Waves and K-Complexes in the Generation of N300 in Auditory and Respiratory-related Evoked Potentials During Early Stage 2 NREM Sleep
The DOI matches its Crossref record.
Abstract
STUDY OBJECTIVES: To determine the scalp topography of the N300 response to stimuli of different modalities and to investigate the relationship of the N300 component to K-complexes and vertex sharp waves seen in the un-averaged EEG. DESIGN: Two experiments were conducted one using auditory; the other using respiratory occlusion stimuli presented during stage 2 sleep. Trials were classified on the basis of whether they produced a K-complex, a vertex sharp wave, or some other response. Auditory stimuli were presented in the form of an oddball paradigm, and averaged separately depending on whether they were "frequent" or "rare". In both experiments, responses were averaged separately based on the appearance of K-complexes, vertex sharps waves, or some "other" response to the stimuli. SETTING: Data were collected in the Melbourne University Sleep Laboratory. PARTICIPANTS: Young healthy male adults, eight in experiment 1 and six in experiment 2. INTERVENTIONS: NA. MEASUREMENTS AND RESULTS: Data were collected from 29 scalp sites. In all cases, N300 amplitude was maximal in the vertex sharp wave averages, despite being clearly present in the averages of K-complexes and "other" responses. The vertex maximal scalp topography of the N300 did not differ across response conditions or as a function of stimulus modality. This is consistent with the N300 being produced by the same intracranial generators in all cases. There were no effects of stimulus or response type on N300 latency. CONCLUSIONS: N300 should be viewed as a multi-modal component with a different underlying generator mechanism than that of the K-complex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review of the evidence for P2 being an independent component process: Age, sleep and modality
Crowley, K. E., & Colrain, I. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.11.021 · Cited by 853
Self-citationTriggering sleep slow waves by transcranial magnetic stimulation
Massimini, M., Ferrarelli, F., Esser, S. K., Riedner, B. A., Huber, R., Murphy, M., Peterson, M. J., & Tononi, G. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702495104 · Cited by 489
The Visual Scoring of Sleep and Arousal in Infants and Children
Grigg-Damberger, M., Gozal, D., Marcus, C. L., Quan, S. F., Rosen, C. L., Chervin, R. D., Wise, M., Picchietti, D. L., Sheldon, S. H., & Iber, C. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26819 · Cited by 361
The use of evoked potentials in sleep research
Colrain, I. M., & Campbell, K. B. (2007) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2007.05.001 · Cited by 151
Self-citationTemporal dynamics of cortical sources underlying spontaneous and peripherally evoked slow waves
Riedner, B. A., Hulse, B. K., Murphy, M. J., Ferrarelli, F., & Tononi, G. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53839-0.00013-2 · Cited by 130
“The N350 component has often been attributed to vertex sharp waves (Colrain et al 2000).”
Background
Metadata
- Authors
- Colrain, I. M., Webster, K. E., Hirst, G., & Campbell, K. B.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-01
- Volume
- 23
- Issue
- 1
- Pages
- 1-10
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W55364487
- Cited by
- 65
- References
- 0
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Roles of Vertex Sharp Waves and K-Complexes in the Generation of N300 in Auditory and Respiratory-related Evoked Potentials During Early Stage 2 NREM Sleep. https://app.cochat.ai/papers/10.1093/sleep/23.1.1g
- The paper
- Colrain, I. M., Webster, K. E., Hirst, G., & Campbell, K. B. (2000). The Roles of Vertex Sharp Waves and K-Complexes in the Generation of N300 in Auditory and Respiratory-related Evoked Potentials During Early Stage 2 NREM Sleep. Sleep. https://doi.org/10.1093/sleep/23.1.1g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.